Suppr超能文献

部分和完全引导式手术技术用于即刻种植体植入的准确性:体外评估。

Accuracy of partially and fully guided surgical techniques for immediate implant placement: An in vitro assessment.

机构信息

PhD student, Department of Diagnosis and Surgery, São Paulo State University (UNESP), School of Dentistry at Araraquara, Araraquara, São Paulo, Brazil.

Professor, Department of Biologic and Materials Sciences and Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich.

出版信息

J Prosthet Dent. 2023 Feb;129(2):363.e1-363.e7. doi: 10.1016/j.prosdent.2022.11.020. Epub 2022 Dec 26.

Abstract

STATEMENT OF PROBLEM

Optimal implant positioning is essential to achieving predictable results. Computer-guided surgery has been reported to be an accurate technique for implant placement in healed sites, but the accuracy of guided techniques for immediate implant placement into fresh sockets is still unclear.

PURPOSE

The purpose of this experimental randomized split-mouth study in pig jaws was to determine the accuracy of partially and fully guided surgical techniques for immediate implant placement into fresh sockets and to compare 2 different methods of implant position deviations analysis.

MATERIAL AND METHODS

Twenty implants were installed in 10 pig jaws using 2 different techniques: partially guided (n=10) and fully guided (n=10). Cone beam computed tomography and digital scanning were performed before and after the surgical procedure to plan the virtual implant position and fabricate the surgical guide, as well as to determine implant position deviations. Two methods were used to evaluate implant deviations: tomographic and digital scanning. The Shapiro-Wilk test of normality was used. Deviation comparisons were carried out by using paired t tests (α=.05), and intraclass correlation coefficient (ICC) was computed to assess the agreement between the 2 methods of implant deviation analysis.

RESULTS

In the tomographic analysis, the partially guided technique resulted in significantly higher global apical and lateral coronal deviations (2.25 ±0.59 mm; 0.96 ±0.55 mm) than fully guided (1.52 ±0.89 mm; 0.75 ±0.52 mm) (P<.01 and P<.05, respectively). The analysis performed using digital scanning showed significantly higher angular, global apical, and lateral apical deviations in the partially guided (6 ±3.28 degrees; 2.49 ±1.03 mm; 2.16 ±1.07 mm) technique than in the fully guided (3.32 ±1.84 degrees; 1.5 ±0.58 mm; 0.98 ±0.67 mm) (P<.05). An ICC of 0.522 between the 2 methods of implant deviation analysis was obtained.

CONCLUSIONS

The partially guided technique was less accurate than the fully guided technique for immediate implant placement into fresh sockets. A moderate concordance was observed between cone beam computed tomography and digital scanning analyses, suggesting that more studies are required to validate and to define the most reliable method of measuring implant deviation.

摘要

问题陈述

最佳种植体定位对于实现可预测的结果至关重要。计算机引导手术已被报道为一种在愈合部位放置种植体的准确技术,但引导技术在即刻植入新鲜牙槽窝中的准确性仍不清楚。

目的

本研究通过在猪颌骨中进行的一项实验性随机分口研究,旨在确定部分和完全引导手术技术在即刻植入新鲜牙槽窝中的准确性,并比较两种不同的种植体位置偏差分析方法。

材料与方法

将 20 个种植体分别使用两种不同的技术(部分引导,n=10;完全引导,n=10)植入 10 个猪颌骨中。在手术前后分别进行锥形束计算机断层扫描和数字扫描,以规划虚拟种植体位置并制作手术导板,并确定种植体位置偏差。使用两种方法评估种植体偏差:断层扫描和数字扫描。使用 Shapiro-Wilk 正态性检验。使用配对 t 检验(α=.05)进行偏差比较,并计算组内相关系数(ICC)以评估两种种植体偏差分析方法的一致性。

结果

在断层扫描分析中,部分引导技术的整体根尖和冠侧向偏差显著高于完全引导技术(2.25±0.59mm;0.96±0.55mm)(P<.01 和 P<.05)。使用数字扫描进行的分析显示,部分引导技术的角度、整体根尖和根尖侧向偏差显著高于完全引导技术(6±3.28°;2.49±1.03mm;2.16±1.07mm)(P<.05)。两种种植体偏差分析方法的 ICC 为 0.522。

结论

与完全引导技术相比,部分引导技术在即刻植入新鲜牙槽窝中的准确性较低。在锥形束计算机断层扫描和数字扫描分析之间观察到中度一致性,表明需要进行更多研究以验证和定义测量种植体偏差最可靠的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验