Suppr超能文献

通过视网膜电图对锥体光谱分类进行表征。

Characterizing cone spectral classification by optoretinography.

作者信息

Pandiyan Vimal Prabhu, Schleufer Sierra, Slezak Emily, Fong James, Upadhyay Rishi, Roorda Austin, Ng Ren, Sabesan Ramkumar

机构信息

Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA, USA.

Graduate Program in Neuroscience, University of Washington, Seattle, WA, USA.

出版信息

Biomed Opt Express. 2022 Nov 22;13(12):6574-6594. doi: 10.1364/BOE.473608. eCollection 2022 Dec 1.

Abstract

Light propagation in photoreceptor outer segments is affected by photopigment absorption and the phototransduction amplification cascade. Photopigment absorption has been studied using retinal densitometry, while recently, optoretinography (ORG) has provided an avenue to probe changes in outer segment optical path length due to phototransduction. With adaptive optics (AO), both densitometry and ORG have been used for cone spectral classification based on the differential bleaching signatures of the three cone types. Here, we characterize cone classification by ORG, implemented in an AO line-scan optical coherence tomography (OCT), and compare it against densitometry. The cone mosaics of five color normal subjects were classified using ORG showing high probability (∼0.99), low error (<0.22%), high test-retest reliability (∼97%), and short imaging durations (< 1 hour). Of these, the cone spectral assignments in two subjects were compared against AO-scanning laser opthalmoscope densitometry. High agreement (mean: 91%) was observed between the two modalities in these two subjects, with measurements conducted 6-7 years apart. Overall, ORG benefits from higher sensitivity and dynamic range to probe cone photopigments compared to densitometry, and thus provides greater fidelity for cone spectral classification.

摘要

光感受器外段中的光传播受光色素吸收和光转导放大级联的影响。光色素吸收已通过视网膜密度测定法进行研究,而最近,视网膜光成像(ORG)为探究光转导引起的外段光程长度变化提供了一条途径。借助自适应光学(AO)技术,密度测定法和ORG都已基于三种视锥细胞类型的差异漂白特征用于视锥细胞光谱分类。在此,我们描述了在AO线扫描光学相干断层扫描(OCT)中实现的ORG视锥细胞分类,并将其与密度测定法进行比较。使用ORG对五名色觉正常受试者的视锥细胞镶嵌图进行分类,结果显示其具有高概率(约0.99)、低误差(<0.22%)、高重测可靠性(约97%)和短成像持续时间(<1小时)。其中,对两名受试者的视锥细胞光谱分配结果与AO扫描激光检眼镜密度测定法进行了比较。在这两名受试者中,两种方法在相隔6至7年进行测量时观察到高度一致性(平均值:91%)。总体而言,与密度测定法相比,ORG在探测视锥细胞光色素方面具有更高的灵敏度和动态范围,因此为视锥细胞光谱分类提供了更高的保真度。

相似文献

1
Characterizing cone spectral classification by optoretinography.通过视网膜电图对锥体光谱分类进行表征。
Biomed Opt Express. 2022 Nov 22;13(12):6574-6594. doi: 10.1364/BOE.473608. eCollection 2022 Dec 1.

引用本文的文献

本文引用的文献

2
Patches of Dysflective Cones in Eyes With No Known Disease.眼部无已知疾病的失谐锥体斑。
Invest Ophthalmol Vis Sci. 2022 Jan 3;63(1):29. doi: 10.1167/iovs.63.1.29.
8
Mechanisms of Light-Induced Deformations in Photoreceptors.光感受器中光诱导变形的机制。
Biophys J. 2020 Oct 20;119(8):1481-1488. doi: 10.1016/j.bpj.2020.09.005. Epub 2020 Sep 16.