Suppr超能文献

基于超声的定量肝脂肪含量测量在呼吸相位之间有差异吗?

Do Ultrasound Based Quantitative Hepatic Fat Content Measurements Have Differences Between Respiratory Phases?

机构信息

Department of Radiology, Gazi University Faculty of Medicine, Yenimahalle, Ankara, Turkey.

Department of Radiology, Gazi University Faculty of Medicine, Yenimahalle, Ankara, Turkey.

出版信息

Acad Radiol. 2023 Sep;30(9):1832-1837. doi: 10.1016/j.acra.2022.12.021. Epub 2023 Jan 9.

Abstract

RATIONALE AND OBJECTIVES

The recently developed ultrasound based tools using attenuation coefficient (AC) and scatter distribution coefficient (SDC) values can be used to quantify hepatic fat content in patients with non-alcoholic fatty liver disease (NAFLD). However, currently the impact of respiratory phase on these measurements is not known. The purpose of this study is to compare AC and SDC measurements acquired at peak inspiration and end expiration phases.

MATERIALS AND METHODS

AC and SDC measurements were obtained in 50 patients with NAFLD. Tissue Attenuation Imaging (TAI) and Tissue Scatter Distribution Imaging (TSI) tools were utilized to measure AC and SDC values, respectively. Five measurements were performed at respiratory phases using TAI and TSI tools and the median values were noted. Subgroup analyses were performed and Wilcoxon signed rank test was used for comparison of the measurements.

RESULTS

The median values of the AC measurements at peak inspiration and end expiration phases were 0.87 dB/cm/MHz and 0.89 dB/cm/MHz, respectively. The median values of the SDC measurements at peak inspiration and end expiration phases were 97.91 and 96.62, respectively. There were no statistically significant differences in AC and SDC measurements between the respiratory phases except for AC measurements in BMI <30 kg/m subgroup.

CONCLUSION

Our results revealed that respiratory phases have no impact on SDC measurements. However, while the AC measurements in BMI ≥30 kg/m subgroup showed no significant difference, there was a significant difference in AC measurements in BMI <30 kg/m subgroup between the respiratory phases.

摘要

原理和目的

最近开发的基于衰减系数(AC)和散射分布系数(SDC)值的超声工具可用于定量非酒精性脂肪肝(NAFLD)患者的肝脂肪含量。然而,目前尚不清楚这些测量值受呼吸相位的影响。本研究的目的是比较吸气峰值和呼气末期时获取的 AC 和 SDC 测量值。

材料和方法

对 50 名 NAFLD 患者进行了 AC 和 SDC 测量。使用组织衰减成像(TAI)和组织散射分布成像(TSI)工具分别测量 AC 和 SDC 值。使用 TAI 和 TSI 工具在呼吸相进行了 5 次测量,并记录中位数。进行了亚组分析,并使用 Wilcoxon 符号秩检验比较测量值。

结果

吸气峰值和呼气末期时的 AC 测量中位数分别为 0.87 dB/cm/MHz 和 0.89 dB/cm/MHz。吸气峰值和呼气末期时的 SDC 测量中位数分别为 97.91 和 96.62。除 BMI<30kg/m 亚组的 AC 测量值外,呼吸相之间的 AC 和 SDC 测量值无统计学差异。

结论

我们的结果表明,呼吸相不影响 SDC 测量值。然而,在 BMI≥30kg/m 亚组中,AC 测量值无显著差异,但在 BMI<30kg/m 亚组中,呼吸相之间的 AC 测量值存在显著差异。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验