Department of Neonatology, Institute of Child Health, Sir Ganga Ram Hospital, Rajinder Nagar, New Delhi
Department of Neonatology, Institute of Child Health, Sir Ganga Ram Hospital, Rajinder Nagar, New Delhi.
Indian Pediatr. 2023 Jan 15;60(1):72-74. doi: 10.1007/s13312-023-2700-0.
We retrieved data of ultrasound-guided neonatal internal jugular vein (IJV) cannulations done between November, 2020 and March, 2021. Of the 33 ultrasound-guided IJV cannulation in neonates, 32 were successful with overall success rate of 97%. Median (IQR) number of attempts per insertion was 2 (1,3.5). There were no major complications observed during the insertion of the catheter. In one instance, inadvertent carotid artery puncture was encountered, without significant bleeding.
我们检索了 2020 年 11 月至 2021 年 3 月期间进行的超声引导新生儿颈内静脉(IJV)置管的数据。在 33 例超声引导的新生儿 IJ 静脉置管中,有 32 例成功,总成功率为 97%。每插入一次的中位数(IQR)尝试次数为 2(1,3.5)。在插入导管过程中未观察到重大并发症。有一例意外刺穿颈总动脉,但无明显出血。