Suppr超能文献

双能 X 射线吸收法在非西班牙裔白种人身上产生的测量误差大于西班牙裔人。

Dual energy X-ray absorptiometry produces larger measurement error in non-Hispanic Caucasians than Hispanics.

机构信息

School of Health and Rehabilitation Science, College of Medicine, The Ohio State University, Columbus, OH 43210, USA; College of Nursing and Health Sciences, Texas A&M International University, Laredo, TX, USA.

College of Arts and Sciences, Shenandoah University, Winchester, VA, USA.

出版信息

Clin Nutr ESPEN. 2023 Feb;53:120-125. doi: 10.1016/j.clnesp.2022.12.012. Epub 2022 Dec 11.

Abstract

BACKGROUND

Dual energy X-ray absorptiometry (DXA) is often used as a criterion measure in body composition research and in clinical settings for the estimate of body fat percent (%Fat). The accuracy of DXA for predicting %Fat has primarily been conducted in non-Hispanic populations.

AIM

The purpose of this study was to determine the agreement of DXA-derived %Fat in Hispanic and non-Hispanic Caucasian adults.

METHODS

The sample consisted of Hispanic males (n = 96) and females (n = 102) and non-Hispanic Caucasian males (n = 145) and females (n = 161). The %Fat of a whole-body DXA scan was compared against a criterion 4-compartment (4C) model via constant error (CE = DXA - 4C model) and 95% limits of agreement. Also, a 2 × 2 factorial ANOVA, using CE as a dependent variable, was conducted to examine the main and interaction effects of sex and ethnicity.

RESULTS

When compared to the 4C model, DXA overestimated %Fat by 4.0% in Hispanics and 5.5% in non-Hispanic Caucasians (all p < 0.05). The 95% limits of agreement ranged from ±5.5% to ±5.9% for all group comparisons. The 2 × 2 factorial ANOVA indicated the CE was greater in non-Hispanic Caucasians than Hispanics (CE difference = 1.5%; p < 0.05).

CONCLUSION

Our findings revealed that DXA significantly overestimates %Fat in both populations (Hispanics and non-Hispanic Caucasians), when compared to a 4C model, regardless of sex (male or female). However, the error is more profound in non-Hispanic Caucasian adults. It is worth nothing that DXA may be useful for tracking changes in body composition that occur throughout a lifestyle intervention. Nonetheless, practitioners should be aware that the estimate of %Fat from DXA may be larger than the actual values obtained from a 4C model.

摘要

背景

双能 X 射线吸收法(DXA)常用于身体成分研究和临床环境中,用于估计体脂肪百分比(%Fat)。DXA 预测%Fat 的准确性主要在非西班牙裔人群中进行。

目的

本研究旨在确定 DXA 衍生的西班牙裔和非西班牙裔白种成年人%Fat 的一致性。

方法

该样本包括西班牙裔男性(n=96)和女性(n=102)以及非西班牙裔白种男性(n=145)和女性(n=161)。通过恒误差(CE=DXA-4C 模型)和 95%一致性界限,将全身 DXA 扫描的%Fat 与 4 compartment(4C)模型进行比较。此外,使用 CE 作为因变量,进行了 2×2 析因方差分析,以检验性别和种族的主要和交互作用效应。

结果

与 4C 模型相比,DXA 高估了西班牙裔的%Fat,高估了 4.0%,而非西班牙裔白种人高估了 5.5%(均 p<0.05)。所有组比较的 95%一致性界限范围为±5.5%至±5.9%。2×2 析因方差分析表明,CE 在非西班牙裔白种人而非西班牙裔中更高(CE 差异=1.5%;p<0.05)。

结论

我们的研究结果表明,与 4C 模型相比,DXA 无论性别(男性或女性),在两种人群(西班牙裔和非西班牙裔白种人)中均显著高估%Fat。然而,非西班牙裔白种成年人的误差更大。值得注意的是,DXA 可能有助于跟踪生活方式干预过程中身体成分的变化。尽管如此,从业者应该注意,DXA 估计的%Fat 可能大于从 4C 模型获得的实际值。