Suppr超能文献

评价两种用于小型犬经食管超声心动图的探头:成像能力、图像质量和可用性。

Evaluation of two probes for transesophageal echocardiography in small dogs: imaging capabilities, image quality, and usability.

机构信息

Department of Small Animal Clinical Sciences, School of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX, USA.

Department of Small Animal Clinical Sciences, School of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX, USA.

出版信息

J Vet Cardiol. 2023 Feb;45:41-49. doi: 10.1016/j.jvc.2022.12.005. Epub 2022 Dec 30.

Abstract

INTRODUCTIONS

Patient size is a limiting factor for transesophageal echocardiography (TEE) in small dogs. The objective of this study was to describe imaging capabilities of two probes for TEE in small dogs.

ANIMALS, MATERIALS, AND METHODS: Prospective study in 10 client-owned dogs weighing <4 kg with congenital heart disease (CHD). Dogs had TEE performed with a microprobe (10T-D, GE Medical) and intracardiac echocardiography (ICE) catheter-based probe (AcuNav™, Biosense Webster) in the esophagus in alternating order. Ease of placement, ability to acquire images of the CHD, image quality, and probe limitations were recorded.

RESULTS

Median weight was 2.4 kg (range, 1.0-3.2). Congenital abnormalities included patent ductus arteriosus (n = 9) and pulmonary valve stenosis (n = 1). The 10T-D microprobe was easy to place (n = 8) or achievable with gentle manipulation (n = 2), and image quality of the CHD was optimal (n = 8), adequate (n = 1), or poor (n = 1). The ICE probe was difficult to place in the esophagus even with an external support system (n = 9) or could not be placed (n = 1), and image quality of the CHD was optimal (n = 2), adequate (n = 3), or poor (n = 5). Both probes provided images in a 1.0-kg dog. Probe limitations included lack of lateral motion (microprobe), the need for an external support system (ICE probe) and inability to consistently maintain contact with the esophagus (ICE probe).

CONCLUSION

The 10T-D microprobe provided high-quality TEE images more consistently than the ICE probe in the majority of dogs in this study; however, the lack of lateral motion can diminish its utility in some dogs.

摘要

介绍

对于小型犬,经食管超声心动图(TEE)的患者体型是一个限制因素。本研究的目的是描述两种 TEE 探头在小型犬中的成像能力。

动物、材料和方法:对 10 只体重<4kg 的患有先天性心脏病(CHD)的患犬进行前瞻性研究。使用微探头(10T-D,GE Medical)和基于心内超声心动图(ICE)导管的探头(AcuNav™,Biosense Webster)在食管中依次进行 TEE。记录探头的放置难易程度、获取 CHD 图像的能力、图像质量和探头局限性。

结果

中位体重为 2.4kg(范围,1.0-3.2kg)。先天性异常包括动脉导管未闭(n=9)和肺动脉瓣狭窄(n=1)。10T-D 微探头易于放置(n=8)或通过轻柔操作即可获得(n=2),CHD 的图像质量为最佳(n=8)、足够(n=1)或较差(n=1)。即使使用外部支撑系统(n=9),ICE 探头也很难放入食管,或者无法放置(n=1),CHD 的图像质量为最佳(n=2)、足够(n=3)或较差(n=5)。两种探头均可在 1.0kg 犬中提供图像。探头局限性包括缺乏侧向运动(微探头)、需要外部支撑系统(ICE 探头)和无法始终保持与食管接触(ICE 探头)。

结论

在本研究的大多数犬中,10T-D 微探头比 ICE 探头更一致地提供高质量的 TEE 图像;然而,缺乏侧向运动可能会降低其在某些犬中的应用价值。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验