Suppr超能文献

不使用牵引台的情况下,行动力髋螺钉固定治疗股骨转子间骨折患者的平均尖端顶点距:一项描述性的横断面研究。

Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study.

机构信息

Department of Orthopedics, B&B Hospital, Gwarko, Lalitpur, Nepal.

出版信息

JNMA J Nepal Med Assoc. 2022 Dec 1;60(256):1021-1025. doi: 10.31729/jnma.7766.

Abstract

INTRODUCTION

Dynamic Hip Screw fixation has shown to be equally effective compared to cephalomedullary nailing. The effectiveness of dynamic hip screw fixation for pertrochanteric fractures without using traction table is not well investigated. This study aimed to find out the mean tip apex distance in patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table.

METHODS

A descriptive cross-sectional study was conducted among patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table between 1 September 2021 and 30 June 2022, after getting approval from institutional review committee (Reference number: IRC-2021-08-23-02). All patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table were included in the study. Patients with pre-existing ipsilateral or contralateral hip deformity, contra-lateral hip prosthesis, bilateral hip fractures, and history of prior ipsilateral hip surgeries were excluded. Point estimate and 95% confidence interval were calculated.

RESULTS

Among 45 patients, the mean tip apex distance was 20.45±6.13 mm (18.66-22.24 mm, 95% Confidence Interval). Among 45 patients, 24 (53.33%) were males and 21 (46.66%) were females. The average age of the participants was 67.75±21.33 years.

CONCLUSIONS

The mean tip apex distance in patients undergoing dynamic hip Screw fixation for pertrochanteric fractures without using traction table was similar to that reported in other international studies.

KEYWORDS

fracture fixation; hip fractures; operating tables.

摘要

简介

动力髋螺钉固定与股骨近端髓内钉固定的效果相当。在不使用牵引床的情况下,动力髋螺钉固定治疗股骨转子间骨折的效果尚未得到充分研究。本研究旨在探讨不使用牵引床行动力髋螺钉固定治疗股骨转子间骨折患者的尖端顶点距离的平均值。

方法

本研究为 2021 年 9 月 1 日至 2022 年 6 月 30 日期间进行不使用牵引床的动力髋螺钉固定治疗股骨转子间骨折的患者的描述性横断面研究,该研究获得了机构审查委员会的批准(参考编号:IRC-2021-08-23-02)。所有进行不使用牵引床的动力髋螺钉固定治疗股骨转子间骨折的患者均被纳入研究。排除存在同侧或对侧髋部畸形、对侧髋部假体、双侧髋部骨折和同侧髋部手术史的患者。计算了点估计值和 95%置信区间。

结果

在 45 名患者中,尖端顶点距离的平均值为 20.45±6.13mm(18.66-22.24mm,95%置信区间)。在 45 名患者中,24 名(53.33%)为男性,21 名(46.66%)为女性。参与者的平均年龄为 67.75±21.33 岁。

结论

不使用牵引床行动力髋螺钉固定治疗股骨转子间骨折患者的尖端顶点距离与其他国际研究报道的相似。

关键词

骨折固定术;髋部骨折;手术台。

相似文献

3
Does Computer-assisted Surgery Improve Lag Screw Placement During Cephalomedullary Nailing of Intertrochanteric Hip Fractures?
Clin Orthop Relat Res. 2020 Sep;478(9):2132-2144. doi: 10.1097/CORR.0000000000001306.
6
[Pertrochanteric fractures: a randomized prospective study comparing dynamic screw plate and intramedullary fixation].
Rev Chir Orthop Reparatrice Appar Mot. 2005 Dec;91(8):732-6. doi: 10.1016/s0035-1040(05)84484-8.
9
130- versus 135-degree sliding hip screws and failure in pertrochanteric hip fractures.
ANZ J Surg. 2014 Dec;84(12):949-54. doi: 10.1111/ans.12713. Epub 2014 Jun 5.

本文引用的文献

4
Management of Hip Fractures in Lateral Position without a Fracture Table.
Arch Bone Jt Surg. 2014 Sep;2(3):168-73. Epub 2014 Sep 15.
5
Antirotation proximal femoral nail versus dynamic hip screw for intertrochanteric fractures: a meta-analysis of randomized controlled studies.
Orthop Traumatol Surg Res. 2013 Jun;99(4):377-83. doi: 10.1016/j.otsr.2012.12.019. Epub 2013 May 23.
6
Dynamic hip screw blade fixation for intertrochanteric hip fractures.
J Orthop Surg (Hong Kong). 2012 Dec;20(3):302-6. doi: 10.1177/230949901202000307.
7
Traction table-related complications in orthopaedic surgery.
J Am Acad Orthop Surg. 2010 Nov;18(11):668-75. doi: 10.5435/00124635-201011000-00004.
9
Conventional muscle-reflection approach versus mini-incision muscle-splitting approach in dynamic hip screw fixation.
J Orthop Surg (Hong Kong). 2008 Aug;16(2):156-61. doi: 10.1177/230949900801600205.
10
[Pertrochanteric fractures: a randomized prospective study comparing dynamic screw plate and intramedullary fixation].
Rev Chir Orthop Reparatrice Appar Mot. 2005 Dec;91(8):732-6. doi: 10.1016/s0035-1040(05)84484-8.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验