Suppr超能文献

手持式超声设备与传统超声在帕金森病患者经颅超声中的比较。

Comparison between a handheld ultrasound device and a traditional ultrasound for performing transcranial sonography in patients with Parkinson's disease.

机构信息

Departamento de Radiologia, Hospital Universitário Gaffrée e Guinle, Rio de Janeiro, Brazil.

Departamento de Neurologia, Hospital Universitário Gaffrée e Guinle, Rio de Janeiro, Brazil.

出版信息

Brain Behav. 2023 Feb;13(2):e2891. doi: 10.1002/brb3.2891. Epub 2023 Jan 27.

Abstract

OBJECTIVE

The aim of this study is to compare a portable ultrasound (US) device and a traditional US for performing transcranial ultrasonography (CCT) in patients with Parkinson's disease (PD).

METHODS

This is a cross-sectional, observational, and analytical study. The study recruited a total of 129 individuals from two public hospitals in the city of Rio de Janeiro in a prospective and non-randomized manner between September 2019 and July 2021 as follows: group A with 31 patients with PD, group B with 65 patients with PD, and group C with 64 healthy individuals. Group A was used to collect data to establish the agreement analysis of the TCS measurements between the two devices. Groups B and C provided data for constructing the receiver operating characteristic curve for the handheld US. The subjects underwent the assessment of the transtemporal bone window (TW) quality, the mesencephalon area, the size of the third ventricle, and the substantia nigra (SN) hyperechogenicity area.

RESULTS

There was a good agreement between the methods regarding the quality of the TW-Kappa concordance coefficient of 100% for the right TW and 83% for the left, the midbrain area-intraclass correlation coefficient (ICC) of 69%, the SN area ICC = 90% for the right SN and 93% for the left and the size of the third ventricle ICC = 96%. The cutoff point for the SN echogenic area in the handheld US was 0.20 cm .

CONCLUSIONS

The handheld US is a viable imaging method for performing TCS because it shows good agreement with the measurements performed with traditional equipment, and the measurement of SN echogenic area for PD diagnosis presents good sensitivity and specificity.

摘要

目的

本研究旨在比较便携式超声(US)设备和传统超声在帕金森病(PD)患者中进行经颅超声检查(TCS)的效果。

方法

这是一项前瞻性、非随机的横断面、观察性和分析性研究。研究于 2019 年 9 月至 2021 年 7 月在里约热内卢市的两家公立医院共招募了 129 名患者,分为三组:A 组 31 例 PD 患者,B 组 65 例 PD 患者,C 组 64 例健康对照者。A 组用于收集数据以建立两种设备之间 TCS 测量的一致性分析。B 组和 C 组提供数据以构建手持 US 的受试者工作特征曲线。对颞骨窗(TW)质量、中脑面积、第三脑室大小和黑质(SN)高回声面积进行评估。

结果

两种方法在 TW 质量方面具有良好的一致性,右侧 TW 和左侧 TW 的 Kappa 一致性系数分别为 100%和 83%,中脑面积的组内相关系数(ICC)为 69%,右侧 SN 和左侧 SN 的 SN 面积 ICC 分别为 90%和 93%,第三脑室大小的 ICC 为 96%。手持 US 中 SN 高回声区的截断点为 0.20cm。

结论

手持 US 是一种可行的 TCS 成像方法,因为它与传统设备的测量结果具有良好的一致性,并且用于 PD 诊断的 SN 高回声区的测量具有良好的敏感性和特异性。