Accuracy of implant placement using CAD-CAM tooth-supported surgical guides for an auricular prosthesis in vitro.

机构信息

State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Digital Center, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, P. R. China.

Department of Stomatology, The First Medical Centre, Chinese PLA General Hospital, Beijing, P. R. China.

出版信息

J Prosthodont. 2024 Jan;33(1):70-76. doi: 10.1111/jopr.13651. Epub 2023 Feb 19.

Abstract

PURPOSE

To evaluate the accuracy of tooth-supported surgical guides used to place implants in auricular prostheses. The accuracy (trueness and precision) of the implant positions was evaluated, and the difference between the surgical guide with and without retention of the external auditory canal (EAC) was compared.

MATERIALS AND METHODS

This study simulated implant placement in vitro for the treatment of right auricle malformation. Surgical guides and other casts were fabricated using additive manufacturing technology. The casts were divided into 2 groups according to the surgical guide, with 10 bone blocks in each group (with or without the EAC plug (Guides 1 and 2)). Three implant positions (Implants 1-3) were prepared for each bone block using surgical guides. Implant positions were registered using light-body silicone impressions combined with optical surface scans to measure the coronal, apical, depth, and angular deviations. Four deviations of trueness and precision were reported as the mean ± standard deviation, which was analyzed by Student's t-test.

RESULTS

Each group of 10 bone blocks with 30 implant positions was successfully prepared and digitally reproduced as implants. The accuracies of implant position with surgical guides were acceptable when compared with the preoperatively planned implant positions. Compared with the Guide 2 group, there was a significant difference in the apical, depth, and angular deviations of Guide 1 group in terms of precision (p = 0.001). There was a significant difference in the depth deviation of Implant 1 (p = 0.028) and apical deviation of Implant 2 (p < 0.001) compared two groups in terms of trueness. In terms of precision, there was a significant difference in the coronal (p = 0.002), apical (p = 0.001), and depth (p < 0.001) deviation of Implant 1; apical (p = 0.036) and angular (p < 0.001) deviation of Implant 2 also existed significant difference; the coronal deviation of Implant 3 (p = 0.018) also existed significant difference. Moreover, the group with the EAC plug showed lower deviation in precision and a smaller volume in the 95% confidence ellipsoid.

CONCLUSION

Both types of tooth-supported surgical guides can provide acceptable accuracy. A surgical guide with an EAC plug was considered to be more precise.

摘要

目的

评估用于放置耳假体植入物的牙支持式手术导板的准确性。评估了植入物位置的准确性(准确性和精密度),并比较了保留和不保留外耳道(EAC)的手术导板之间的差异。

材料和方法

本研究模拟了右耳廓畸形的植入物放置。使用增材制造技术制造手术导板和其他模型。根据手术导板将模型分为两组,每组 10 个骨块(有和没有 EAC 塞(导板 1 和 2))。使用手术导板为每个骨块准备了 3 个植入物位置(植入物 1-3)。使用光体硅橡胶印模结合光学表面扫描对植入物位置进行注册,以测量冠向、根尖、深度和角度偏差。报告了 4 个准确性和精密度偏差作为平均值±标准差,并通过学生 t 检验进行分析。

结果

成功制备了每组 10 个骨块和 30 个植入物,并作为植入物进行了数字再现。与术前计划的植入物位置相比,使用手术导板的植入物位置精度可接受。与导板 2 组相比,导板 1 组在精度方面的根尖、深度和角度偏差有显著差异(p=0.001)。在准确性方面,两组之间存在显著差异,植入物 1 的深度偏差(p=0.028)和植入物 2 的根尖偏差(p<0.001)。在精度方面,植入物 1 的冠向(p=0.002)、根尖(p=0.001)和深度(p<0.001)偏差、植入物 2 的根尖(p=0.036)和角度(p<0.001)偏差存在显著差异;植入物 3 的冠向偏差(p=0.018)也存在显著差异。此外,带有 EAC 塞的组在精度上偏差较小,95%置信椭圆体的体积也较小。

结论

两种牙支持式手术导板均可提供可接受的准确性。带有 EAC 塞的手术导板被认为更精确。