Suppr超能文献

轮状病毒疫苗试验中抗轮状病毒抗体的测定:免疫分析中疫苗抗原的选择很重要。

Anti-rotavirus antibody measurement in a rotavirus vaccine trial: Choice of vaccine antigen in immunoassays does matter.

机构信息

Division of Viral Diseases, Centers for Diseases Control and Prevention (CDC), Atlanta, GA, USA.

Division of Infectious Diseases, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, Bangladesh.

出版信息

Hum Vaccin Immunother. 2023 Dec 31;19(1):2167437. doi: 10.1080/21645515.2023.2167437. Epub 2023 Jan 30.

Abstract

In a clinical trial of Bangladeshi infants who received three doses of RotaTeq (ages 6, 10, and 14 weeks), we did a head-to-head assessment of two vaccine virus strains to measure rotavirus IgA in sera. Serum samples collected at pre-dose 1 (age 6 weeks) and post-dose 3 (age 22 weeks) were tested for rotavirus IgA by EIA by using the matching vaccine strain (RotaTeq) and a different vaccine strain (Rotarix) as antigens. Overall, rotavirus IgA seropositivity and titers with each antigen were compared. At age 22 weeks (N = 531), the proportion of infants who tested rotavirus IgA seropositive was similar when measured using the RotaTeq (412/531 [78%]) or the Rotarix antigen (403/531 [76%]) in the EIA. However, the IgA geometric mean titer was higher when measured using the RotaTeq antigen as compared to that measured using the Rotarix antigen [218 (95%CI: 176-270) vs. 93 (77-111),  < .0001]. We have compared two globally licensed vaccines, the human monovalent, and the pentavalent reassortant, as antigens on a RotaTeq cohort, resulting in higher estimations of IgA antibodies in the same sample when measured using the RotaTeq antigen. Our findings support matching vaccine antigens in EIA for the most desired immunogenicity testing of the RotaTeq vaccine.

摘要

在一项孟加拉国婴儿接受三剂 RotaTeq(6、10 和 14 周龄)的临床试验中,我们对头对头评估了两种疫苗病毒株,以测量血清中的轮状病毒 IgA。在预剂量 1(6 周龄)和后剂量 3(22 周龄)时采集的血清样本通过 EIA 用匹配的疫苗株(RotaTeq)和不同的疫苗株(Rotarix)作为抗原检测轮状病毒 IgA。总体而言,比较了每种抗原的轮状病毒 IgA 血清阳性率和滴度。在 22 周龄时(N=531),使用 RotaTeq(412/531 [78%])或 Rotarix 抗原(403/531 [76%])进行 EIA 测量时,检测到轮状病毒 IgA 血清阳性的婴儿比例相似。然而,当使用 RotaTeq 抗原测量时,IgA 几何平均滴度高于使用 Rotarix 抗原测量时[218(95%CI:176-270)与 93(77-111),<0.0001]。我们比较了两种全球许可的疫苗,人单价疫苗和五价重组疫苗,作为 RotaTeq 队列中的抗原,当使用 RotaTeq 抗原测量时,同一样本中的 IgA 抗体得到了更高的估计。我们的研究结果支持在 EIA 中匹配疫苗抗原,以进行最期望的 RotaTeq 疫苗免疫原性测试。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e87e/10012887/804480085ae1/KHVI_A_2167437_F0001_B.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验