Suppr超能文献

平台转换锥形连接种植体在牙槽嵴顶下1或2毫米处植入后的边缘骨变化:一项多中心交叉随机对照试验。

Marginal bone changes around platform-switched conical connection implants placed 1 or 2 mm subcrestally: A multicenter crossover randomized controlled trial.

作者信息

Stacchi Claudio, Lamazza Luca, Rapani Antonio, Troiano Giuseppe, Messina Marcello, Antonelli Alessandro, Giudice Amerigo, Lombardi Teresa

机构信息

Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy.

Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Rome, Italy.

出版信息

Clin Implant Dent Relat Res. 2023 Apr;25(2):398-408. doi: 10.1111/cid.13186. Epub 2023 Feb 1.

Abstract

INTRODUCTION

This study analyzes early marginal bone modifications occurring around platform-switched implants with conical connection placed 1 or 2 mm subcrestally.

METHODS

This crossover randomized controlled trial enrolled partially edentulous patients needing two implants in either the posterior maxilla or mandible. Each patient received two platform-switched implants with conical connection inserted 2 mm (Test) and 1 mm (Control) subcrestally. Definitive abutments were immediately connected and, after 4 months of unsubmerged healing, screwed metal-ceramic crowns were delivered. Radiographs were taken at implant placement (T0), prosthesis delivery (T1), and after 1 year of prosthetic loading (T2).

RESULTS

Fifty-one patients (25 males and 26 females; mean age 61.2 ± 12.1 years) totaling 102 implants were included in the final analysis. Mean peri-implant bone level (PBL) reduction from T0 to T2 was not significantly different around Test (0.49 ± 0.32 mm) and Control implants (0.46 ± 0.35 mm; p = 0.66). Multivariate linear regression models highlighted a significant positive correlation between history of periodontitis and PBL reduction. At T2, no Test group implant and 6 Control group implants exhibited PBL below the implant platform (11.8% of Control group implants).

CONCLUSION

No significant differences in peri-implant marginal bone changes were demonstrated after 1 year of prosthetic loading between platform-switched implants with conical connection inserted either 1 or 2 mm subcrestally. However, 2 mm subcrestal placement resulted in deeper implant positioning at T2, with no exposure of treated implant surface and potential preventive effect against subsequent peri-implant pathology.

摘要

引言

本研究分析了在牙槽嵴顶下1或2毫米处植入的带有锥形连接的平台转换种植体周围早期边缘骨的改变情况。

方法

本交叉随机对照试验纳入了上颌后牙区或下颌需要植入两颗种植体的部分牙列缺损患者。每位患者均接受两颗带有锥形连接的平台转换种植体,分别在牙槽嵴顶下2毫米(试验组)和1毫米(对照组)处植入。即刻连接最终基台,在4个月的非潜入式愈合后,安装金属烤瓷冠。在种植体植入时(T0)、义齿安装时(T1)以及义齿加载1年后(T2)拍摄X线片。

结果

最终分析纳入了51例患者(25例男性和26例女性;平均年龄61.2±12.1岁),共102颗种植体。试验组种植体(0.49±0.32毫米)和对照组种植体(0.46±0.35毫米;p = 0.66)从T0到T2的平均种植体周围骨水平(PBL)降低无显著差异。多变量线性回归模型突出显示牙周炎病史与PBL降低之间存在显著正相关。在T2时,试验组没有种植体,对照组有6颗种植体的PBL低于种植体平台(占对照组种植体的11.8%)。

结论

在牙槽嵴顶下1或2毫米处植入带有锥形连接的平台转换种植体,在义齿加载1年后,种植体周围边缘骨变化无显著差异。然而,牙槽嵴顶下2毫米植入在T2时导致种植体定位更深,未暴露种植体处理过的表面,对后续种植体周围病变可能具有预防作用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验