Suppr超能文献

增强端侧吻合至长神经移植物以促进运动神经再生:一项大鼠实验研究。

Supercharge End-to-Side Motor Transfer to a Long Nerve Graft to Enhance Motor Regeneration: An Experimental Rat Study.

机构信息

From the Department of Plastic and Reconstructive Surgery, Chang Gung Memorial Hospital and Chang-Gung University.

出版信息

Plast Reconstr Surg. 2023 Jul 1;152(1):85e-95e. doi: 10.1097/PRS.0000000000010114. Epub 2023 Jun 29.

Abstract

BACKGROUND

Long nerve grafts are prone to chronic denervation, often resulting in unsatisfactory clinical outcomes. The authors aim to investigate whether supercharge end-to-side (SETS) motor nerve transfers to a long nerve graft can potentially enhance nerve regeneration and functional outcomes.

METHODS

A reversed long nerve graft was interposed between the C6 and the musculocutaneous nerve in 48 rats. The motor nerves near the C6 proximally and the musculocutaneous nerve distally were chosen for SETS transfer to the long nerve graft. There were four groups: (A) nerve graft only, (B) proximal SETS transfer, (C) distal SETS transfer, and (D) proximal and distal double SETS transfers. A grooming test was assessed at 4, 8, 12, and 16 weeks postoperatively. Biceps weight, compound muscle action potential amplitude, tetanic contraction force, and histomorphometric analysis of the musculocutaneous nerve were evaluated at 16 weeks.

RESULTS

Long nerve grafts that received SETS transfers (groups B, C, and D) showed superior results compared with the control group. Proximal SETS transfer had significantly better outcomes than distal SETS transfer in electrodiagnostic parameters, whereas double SETS transfer had the highest axonal count and biceps compound muscle action potential amplitude.

CONCLUSION

SETS motor transfers to long nerve grafts can effectively improve functional outcome and optimize nerve graft regeneration to the target nerve.

CLINICAL RELEVANCE STATEMENT

Long nerve grafts yield suboptimal functional results. The experimental study showed that SETS motor transfer to a long nerve graft improves muscle functional outcomes. A double motor SETS transfer provides the best results. Proximal SETS transfer might have more benefits over distal transfer.

摘要

背景

长神经移植物容易发生慢性去神经支配,常导致不理想的临床结果。作者旨在探讨超支侧(SETS)运动神经转移到长神经移植物是否能潜在地增强神经再生和功能结果。

方法

在 48 只大鼠中,将反向长神经移植物置于 C6 和肌皮神经之间。选择 C6 近端和肌皮神经远端的运动神经进行 SETS 转移到长神经移植物。共有四组:(A)神经移植物仅,(B)近端 SETS 转移,(C)远端 SETS 转移,和(D)近端和远端双重 SETS 转移。术后 4、8、12 和 16 周评估梳理试验。16 周时评估二头肌重量、复合肌肉动作电位幅度、强直性收缩力和肌皮神经的组织形态计量学分析。

结果

接受 SETS 转移的长神经移植物(B、C 和 D 组)与对照组相比显示出更好的结果。在电诊断参数方面,近端 SETS 转移明显优于远端 SETS 转移,而双重 SETS 转移具有最高的轴突计数和二头肌复合肌肉动作电位幅度。

结论

SET 运动转移到长神经移植物可以有效改善功能结果并优化神经移植物对目标神经的再生。

临床相关性声明

长神经移植物产生不理想的功能结果。实验研究表明,SET 运动转移到长神经移植物可改善肌肉功能结果。双重运动 SETS 转移提供最佳结果。近端 SETS 转移可能比远端转移具有更多优势。