Suppr超能文献

胫骨单植入物全内骨搬运钉骨搬运

Tibial Bone Transport With a Single Implant All-Internal Bone Transport Nail.

机构信息

Department of Orthopedic Surgery, Medical College of Georgia at Augusta University, Augusta, Georgia; and Medical Student, Medical College of Georgia at Augusta University, Augusta, Georgia; and Texas Tech University Health Sciences Center, El Paso, TX.

出版信息

J Orthop Trauma. 2023 Jul 1;37(7):e294-e300. doi: 10.1097/BOT.0000000000002513.

Abstract

A single implant all-internal magnet-driven bone transport nail (BTN-NuVasive Specialized Orthopaedics Inc) has recently been introduced as a treatment method for segmental tibial bone defects. This innovation provides promise in the management of segmental bone defects because it negates numerous complications associated with circular external fixation and the need for multiple implants when considering hybrid plate-assisted bone segment transport constructs. Given the novelty of the BTN, description of the surgical application and patient outcome measures are scarce in the current literature. To date, we have treated 4 patients with an average age of 27 years (range 19-44 years) using the BTN for segmental tibial defects ranging from 50 to 128 mm. We have accumulated data over an average follow-up of 18.07 months (range 12.96-25.13 months), demonstrating good patient tolerance of the device. Three patients successfully completed their treatment course with a calculated average bone healing index of 41.4 days/cm (range 31.41-54.82 days/cm). One patient was noted to experience an asymptomatic docking site nonunion requiring subsequent surgery for nonunion repair. Implant-associated complications included symptomatic implant, axial malalignment, docking site nonunion, and external remote control technical malfunction. Injury-related complications were encountered and noted to include: superficial infection, wound dehiscence, peroneal tendonitis, and joint rigidity. In this study, the authors present a case series using this implant to date and discuss our experiences with the BTN with reference to clinical indications, tibial bone preparation, BTN implantation, transport protocol, docking site procedure, and clinical/radiographic outcomes.

摘要

一种新型的单植入物全内置磁铁驱动骨搬运钉(BTN-NuVasive Specialized Orthopaedics Inc)已被引入作为治疗节段性胫骨骨缺损的方法。这种创新在节段性骨缺损的管理中具有很大的前景,因为它消除了环形外固定所带来的许多并发症,并且在考虑混合钢板辅助骨段搬运构建物时,不需要多个植入物。鉴于 BTN 的新颖性,目前文献中对其手术应用和患者结果评估的描述很少。迄今为止,我们使用 BTN 治疗了 4 名平均年龄为 27 岁(19-44 岁)的患者,他们的节段性胫骨缺损范围为 50-128mm。我们在平均随访 18.07 个月(12.96-25.13 个月)时积累了数据,显示患者对该设备有良好的耐受性。3 名患者成功完成了他们的治疗疗程,计算出的平均骨愈合指数为 41.4 天/cm(31.41-54.82 天/cm)。1 名患者出现无症状的对接部位骨不连,需要进行后续手术修复骨不连。与植入物相关的并发症包括症状性植入物、轴向对线不良、对接部位骨不连和外部远程控制技术故障。还遇到了与损伤相关的并发症,包括:浅表感染、伤口裂开、腓肠肌腱炎和关节僵硬。在本研究中,作者报告了迄今为止使用该植入物的一系列病例,并讨论了我们在临床适应证、胫骨骨准备、BTN 植入、搬运方案、对接部位程序以及临床/影像学结果方面使用 BTN 的经验。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验