Department of Otolaryngology and Head & Neck Surgery, Izmir Bozyaka Training and Research Hospital, University of Health Sciences, Izmir.
Department of Otolaryngology and Head & Neck Surgery, Istinye University Faculty of Medicine, Liv Hospital Ulus, Turkey.
J Craniofac Surg. 2023 May 1;34(3):881-883. doi: 10.1097/SCS.0000000000008990. Epub 2022 Sep 6.
The aim of this study is to examine the effects of the burr used for hump reduction and osteoplasty on cochlear function.
The design of this study was prospective, randomized, and controlled. Twenty patients who underwent burr-assisted septorhinoplasty were included in the study group. The control group consisted of 20 patients who underwent septoplasty. Pure tone audiometry, distortion product otoacoustic emission test, and tympanometry were performed to determine the auditory functions.
No significant difference was observed between the bone conduction thresholds of the right and left ears in both groups, except for a single frequency (1000 Hz in the left ear) in the control group. There was no significant difference between the 2 groups' air conduction thresholds at frequencies of 500, 1000, 2000, 4000, 6000, and 8000 Hz preoperatively and postoperatively. In addition, the study and control group did not differ significantly in signal-to-noise ratio measurements at frequencies of 500, 1000, 2000, and 4000 Hz. The comparison of preoperative and postoperative otoacoustic emission measurement results of the study group revealed a statistically significant difference only at the frequencies of 2000 Hz in the right ear and 500 Hz in the left ear. Despite those differences, otoacoustic emissions were still present at those frequencies postoperatively.
Our study showed that using burrs during rhinoplasty slightly impacts hearing, but it does not cause significant hearing loss. Burr-assisted rhinoplasty appears to be a safe operation regarding the auditory functions.
本研究旨在探讨用于驼峰缩小和骨成形术的磨头对耳蜗功能的影响。
本研究设计为前瞻性、随机对照研究。将 20 例接受磨头辅助鼻中隔成形术的患者纳入研究组,20 例接受鼻中隔成形术的患者纳入对照组。采用纯音听阈测试、畸变产物耳声发射测试和鼓室导抗测试评估听觉功能。
除对照组中左耳单个频率(1000Hz)外,两组患者的骨导阈值在右耳和左耳均无显著差异。两组患者术前和术后 500、1000、2000、4000、6000 和 8000Hz 的气导阈值均无显著差异。此外,研究组和对照组在 500、1000、2000 和 4000Hz 的信噪比测量值上也无显著差异。研究组术前和术后的耳声发射测量结果比较仅在右耳 2000Hz 和左耳 500Hz 时存在统计学差异。尽管存在这些差异,但术后这些频率仍存在耳声发射。
我们的研究表明,在鼻整形术中使用磨头会对听力产生轻微影响,但不会导致明显的听力损失。磨头辅助鼻整形术似乎对听觉功能是一种安全的手术。