Suppr超能文献

三微针装置在吲哚菁绿荧光淋巴造影中的应用。

The Usefulness of a Three-Microneedle Device for Indocyanine Green Fluorescence Lymphography.

机构信息

Division of Vascular Surgery, Hamamatsu University School of Medicine, Hamamatsu, Japan.

Second Department of Surgery, Hamamatsu University School of Medicine, Hamamatsu, Japan.

出版信息

Lymphat Res Biol. 2023 Aug;21(4):396-402. doi: 10.1089/lrb.2022.0049. Epub 2023 Feb 21.

Abstract

Indocyanine green (ICG) fluorescence lymphography is widely used to diagnose lymphedema. There is little consensus on the appropriate injection method for ICG fluorescence lymphangiography. We used a three-microneedle device (TMD) for skin injection of ICG solution and investigated its usefulness. Thirty healthy volunteers were injected with ICG solution using a 27-gauge (27G) needle in one foot and a TMD in the other foot. Injection-related pain was evaluated using the Numerical Rating Scale (NRS) and Face Rating Scale (FRS). The skin depth of the injected ICG solution was evaluated by injecting the solution into the skin of amputated lower limbs using a 27G needle or TMD using ICG fluorescence microscopy. The median and interquartile range of the NRS scores was 3 (3-4) and 2 (2-4) in the 27G needle and TMD groups, respectively; that of the FRS scores was 2 (2-3) and 2 (1-2) in the 27G needle and TMD groups, respectively. Injection-related pain was significantly lower with the TMD than with the 27G needle. The lymphatic vessels were similarly visible using both needles. The depth of the ICG solution varied for each injection with a 27G needle (400-1200 μm) and was consistent at ∼300-700 μm below the skin surface using the TMD. Injection depth was significantly different between the 27G needle and the TMD. Injection-related pain decreased using the TMD, and ICG solution depth was consistent on fluorescence lymphography. A TMD may be useful for ICG fluorescence lymphography. Clinical Trials Registry (UMIN-CTR; ID: UMIN000033425).

摘要

吲哚菁绿(ICG)荧光淋巴造影术被广泛用于诊断淋巴水肿。对于 ICG 荧光淋巴管造影术的适当注射方法,尚未达成共识。我们使用三微针装置(TMD)进行 ICG 溶液的皮肤注射,并对其进行了评估。

三十名健康志愿者的一只脚使用 27 号(27G)针头,另一只脚使用 TMD 注射 ICG 溶液。使用数字评分量表(NRS)和面部评分量表(FRS)评估注射相关疼痛。通过使用 27G 针头或 TMD 将 ICG 溶液注入截肢下肢的皮肤,评估注入的 ICG 溶液的皮肤深度。使用 ICG 荧光显微镜。NRS 评分的中位数和四分位距分别为 3(3-4)和 2(2-4),FRS 评分分别为 2(2-3)和 2(1-2)在 27G 针头和 TMD 组中。TMD 组的注射相关疼痛明显低于 27G 针头组。两种针头均可见淋巴管。使用 27G 针头(400-1200μm)时,每次注射的 ICG 溶液深度不同,而使用 TMD 时,表皮下约 300-700μm 的深度一致。27G 针头和 TMD 之间的注射深度差异有统计学意义。使用 TMD 可降低注射相关疼痛,荧光淋巴造影术的 ICG 溶液深度一致。TMD 可能对 ICG 荧光淋巴造影术有用。临床试验注册(UMIN-CTR;ID:UMIN000033425)。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验