Suppr超能文献

Different reactivities of H O (H O) with unsaturated and saturated aldehydes: ligand-switching reactions govern the quantitative analytical sensitivity of SESI-MS.

作者信息

Španěl Patrik, Dryahina Kseniya, Omezzine Gnioua Maroua, Smith David

机构信息

J. Heyrovsky Institute of Physical Chemistry of the Czech Academy of Sciences, Prague, Czechia.

Department of Surface and Plasma Science, Faculty of Mathematics and Physics, Charles University, Prague, Czech Republic.

出版信息

Rapid Commun Mass Spectrom. 2023 May 15;37(9):e9496. doi: 10.1002/rcm.9496.

Abstract

RATIONALE

The detection sensitivity of secondary electrospray ionisation mass spectrometry (SESI-MS) is much lower for saturated aldehydes than for unsaturated aldehydes. This needs to be understood in terms of gas phase ion-molecule reaction kinetics and energetics to make SESI-MS analytically more quantitative.

METHODS

Parallel SESI-MS and selected ion flow tube mass spectrometry (SIFT-MS) analyses were carried out of air containing variable accurately determined concentrations of saturated (C5, pentanal; C7, heptanal; C8 octanal) and unsaturated (C5, 2-pentenal; C7, 2-heptenal; C8, 2-octenal) aldehyde vapours. The influence of the source gas humidity and the ion transfer capillary temperature, 250 and 300°C, in a commercial SESI-MS instrument was explored. Separate experiments were carried out using SIFT to determine the rate coefficients, k , for the ligand-switching reactions of the H O (H O) ions with the six aldehydes.

RESULTS

The relative slopes of the plots of SESI-MS ion signal against SIFT-MS concentration were interpreted as the relative SESI-MS sensitivities for these six compounds. The sensitivities for the unsaturated aldehydes were 20 to 60 times greater than for the corresponding C5, C7 and C8 saturated aldehydes. Additionally, the SIFT experiments revealed that the measured k are three or four times greater for the unsaturated than for the saturated aldehydes.

CONCLUSIONS

The trends in SESI-MS sensitivities are rationally explained by differences in the rates of the ligand-switching reactions, which are justified by theoretically calculated equilibrium rate constants derived from thermochemical density functional theory (DFT) calculations of Gibb's free energy changes. The humidity of SESI gas thus favours the reverse reactions of the saturated aldehyde analyte ions, effectively suppressing their signals in contrast to their unsaturated counterparts.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验