Department for Orthopaedics and Traumatology, Med Campus III, Kepler University Hospital, Krankenhausstr. 9, 4020 Linz, Austria.
Johannes Kepler University Linz, Altenberger Str. 96, 4040 Linz, Austria.
Medicina (Kaunas). 2023 Feb 9;59(2):320. doi: 10.3390/medicina59020320.
: Noise exposure during total knee arthroplasty (TKA) has been demonstrated to exceed thresholds that are deemed as over-exposure by industry noise level standards. With orthopedic surgeons being at risk of suffering from Noise Induced Hearing Loss, the purpose of this pilot study was to evaluate the viability of the use of industry grade active noise cancelling headphones (ANCH) during TKA. In this prospective pilot study, 10 TKA were performed. In five of these cases, surgeon, assistant, scrub nurse and anesthetist wore ANCH with automatic noise level dependent noise attenuation above 82 dB. A validated 14-item questionnaire was used after each case to evaluate the quality of communication, performance, teamwork and mental load. In seven cases a calibrated sound level meter was used to measure the operating theatre noise. Peak sound level (LApeak), A-weighted continuous sound level (LAeq) and A-weighted noise exposure averaged for an 8-h time-period (LEPd) were calculated. There was no perceived benefit of ANCH for the surgeons ( = 0.648), assistants ( = 0.908) and scrub nurses ( = 0.251). There was an overall improvement observed by anesthetists ( = 0.001). A worse communication while wearing ANCH was reported by surgeons but not by the rest of the team. Average LApeak was 90.6 ± 3.2 dB(C), LAeq was 61.9 ± 1.0 dB(A) and LEPd was 53.2 ± 1.2 dB(A). Industry grade ANCH seem to provide no benefit for surgeons, assistants and scrub nurses during TKA, while anesthesiologists seem to benefit from the use of ANCH during TKA. Due to the limitations of this pilot study, further studies with larger study populations are necessary to adequately investigate the use of ANCH during TKA.
在全膝关节置换术 (TKA) 过程中,已经证实噪声暴露超过了行业噪声水平标准所认为的过度暴露阈值。由于骨科医生有患噪声性听力损失的风险,因此本初步研究的目的是评估在 TKA 过程中使用工业级有源降噪耳机 (ANCH) 的可行性。在这项前瞻性初步研究中,进行了 10 例 TKA。在其中 5 例中,外科医生、助手、洗手护士和麻醉师佩戴了 ANCH,其自动噪声水平相关噪声衰减超过 82 dB。在每次手术后使用经过验证的 14 项问题清单评估沟通质量、手术表现、团队合作和精神负荷。在 7 例中,使用校准声级计测量手术室噪声。计算了峰值声级 (LApeak)、A 加权连续声级 (LAeq) 和 8 小时平均 A 加权噪声暴露 (LEPd)。外科医生 ( = 0.648)、助手 ( = 0.908) 和洗手护士 ( = 0.251) 均未感觉到 ANCH 的好处。麻醉师观察到整体情况有所改善 (= 0.001)。佩戴 ANCH 时,外科医生报告沟通情况更差,但其他团队成员并未报告。平均 LApeak 为 90.6 ± 3.2 dB(C),LAeq 为 61.9 ± 1.0 dB(A),LEPd 为 53.2 ± 1.2 dB(A)。在 TKA 期间,工业级 ANCH 似乎对外科医生、助手和洗手护士没有好处,而麻醉师在 TKA 期间使用 ANCH 似乎受益。由于本初步研究的局限性,需要进一步进行更大的研究人群的研究,以充分调查在 TKA 过程中使用 ANCH 的情况。