Godage Nipunika H, Cudjoe Erasmus, Chau Tue, Gionfriddo Emanuela
Department of Chemistry and Biochemistry, College of Natural Sciences and Mathematics, The University of Toledo, Toledo, OH 43606, USA.
School of Green Chemistry and Engineering, The University of Toledo, Toledo, OH 43606, USA.
Anal Bioanal Chem. 2023 Jul;415(18):4423-4434. doi: 10.1007/s00216-023-04589-8. Epub 2023 Feb 25.
Analysis of biofluids, such as plasma, can be used to investigate occupational pesticide exposure in the agricultural industry. Considering the chemical complexity and variability of plasma samples, any protocol for pesticide analysis should achieve efficient sample cleanup to minimize matrix effects and enhance method sensitivity through analyte pre-concentration. In this work, a high-throughput method was developed for analysis of 79 pesticides, commonly used in agricultural practices, in human plasma, using biocompatible solid-phase microextraction (SPME) coupled to liquid chromatography-tandem mass spectrometry. An SPME method was developed using a biocompatible hydrophilic-lipophilic balance/polyacrylonitrile (HLB/PAN) extraction phase and demonstrated negligible matrix effects. The performance of the developed SPME method was compared to a QuEChERS -Quick, Easy, Cheap, Effective, Rugged, and Safe- method, the most common sample preparation and cleanup approach for pesticide analysis in complex matrices. Comparable accuracy and precision were achieved for both methods, with accuracy values within 70-120% and relative standard deviation < 15%. Overall, the developed SPME and QuEChERS methods extracted 79 out of 82 monitored pesticides in human plasma. The SPME protocol demonstrated higher sensitivity than the QuEChERS method and a drastic reduction of matrix effects.
对生物流体(如血浆)进行分析,可用于调查农业行业中的职业性农药暴露情况。考虑到血浆样本的化学复杂性和变异性,任何农药分析方案都应实现高效的样本净化,以最大限度地减少基质效应,并通过分析物预浓缩提高方法的灵敏度。在这项工作中,开发了一种高通量方法,用于分析人体血浆中79种农业常用农药,该方法采用生物相容性固相微萃取(SPME)与液相色谱-串联质谱联用。使用生物相容性亲水亲脂平衡/聚丙烯腈(HLB/PAN)萃取相开发了一种SPME方法,该方法显示出可忽略不计的基质效应。将所开发的SPME方法的性能与QuEChERS(快速、简便、廉价、有效、耐用和安全)方法进行了比较,QuEChERS方法是复杂基质中农药分析最常用的样品制备和净化方法。两种方法均实现了可比的准确度和精密度,准确度值在70%-120%之间,相对标准偏差<15%。总体而言,所开发的SPME方法和QuEChERS方法在人体血浆中提取了82种监测农药中的79种。SPME方案显示出比QuEChERS方法更高的灵敏度,且基质效应大幅降低。