Suppr超能文献

肩袖修复后肌腱硬度变化的系统时间评估。

A Systematic Temporal Assessment of Changes in Tendon Stiffness Following Rotator Cuff Repair.

机构信息

University of New South Wales, Sydney, New South Wales, Australia.

出版信息

J Ultrasound Med. 2023 Aug;42(8):1799-1808. doi: 10.1002/jum.16201. Epub 2023 Feb 27.

Abstract

OBJECTIVES

How the material properties of the human supraspinatus tendon change following arthroscopic rotator cuff repair is undetermined. Shear wave elastography ultrasound is a relatively new, noninvasive measure of tissue stiffness. We aimed to evaluate any temporal changes in stiffness and/or thickness of supraspinatus tendons in humans following primary arthroscopic rotator cuff repair.

METHODS

Shear wave elastography was performed at three predetermined regions by a single sonographer at 1-, 6-, 12-, 24-, and 52 weeks postoperatively in 50 consecutive single-row inverted mattress primary arthroscopic rotator cuff repairs. One-way ANOVA with Tukey's correction and Spearman's correlation tests was performed.

RESULTS

Of 50 patients, two retore by 1-week and were excluded. Two patients retore at 6 weeks, two at 12 weeks, and one at 24 weeks. The mean tendon stiffness in 48 patients at the tendon footprint increased by 21% (1.32 m/s) at 6 months (P < .001), with the lateral tendon stiffening before the medial tendon. Tendon thickness decreased by 11% (0.6 mm) at 6 weeks (P = .008), then stabilized to 24 weeks. Tendons that were less elastographically stiff at 1 week were more likely to be thinner at 6-weeks (r = .38, P = .010).

CONCLUSIONS

The data supports the hypothesis that rotator cuff tendons repaired using the single-row inverted-mattress technique take 6 weeks to heal to bone. Unlike in other tendons, there was no hypertrophic healing response. Prior to 6 weeks, the tendon may stretch/thin-out, particularly if its material properties, as assessed by shear wave elastography, are inferior. The material properties of the tendon improved at the tendon insertion site first, then medially out to 12 months post-repair.

摘要

目的

关节镜下肩袖修复后,人类肩袖冈上肌腱的物质特性如何变化尚不确定。剪切波弹性成像超声是一种相对较新的、非侵入性的组织硬度测量方法。我们旨在评估原发性关节镜下肩袖修复后人类冈上肌腱的硬度和/或厚度是否存在任何时间变化。

方法

由一名超声医师在术后 1、6、12、24 和 52 周,通过单次剪切波弹性成像,在 50 例连续行单排倒置褥式关节镜下肩袖修复术患者的三个预定部位进行检测。采用单因素方差分析(ANOVA),并结合 Tukey 校正和 Spearman 相关性检验进行分析。

结果

在 50 例患者中,有 2 例在 1 周时出现再撕裂,被排除在外。有 2 例在 6 周时、2 例在 12 周时、1 例在 24 周时出现再撕裂。48 例患者的冈上肌腱止点处肌腱硬度在 6 个月时增加了 21%(1.32m/s)(P<.001),外侧肌腱比内侧肌腱先变硬。肌腱厚度在 6 周时减少了 11%(0.6mm)(P=.008),然后在 24 周时稳定下来。在第 1 周时弹性成像硬度较低的肌腱,在第 6 周时更有可能变薄(r=0.38,P=.010)。

结论

该数据支持以下假设,即采用单排倒置褥式技术修复的肩袖肌腱需要 6 周才能愈合至骨。与其他肌腱不同,冈上肌腱没有过度愈合反应。在 6 周之前,肌腱可能会拉伸/变薄,尤其是如果其作为剪切波弹性成像评估的材料特性较差。肌腱在肌腱止点处的性质首先得到改善,然后在 12 个月时向内侧改善。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验