Suppr超能文献

肩袖修复术后缝线的转归

The fate of sutures post rotator cuff repair.

作者信息

Chua Alynna X Y, Hackett Lisa M, Lam Patrick H, Murrell George A C

机构信息

Orthopaedic Research Institute, St George Hospital Campus, University of New South Wales, Sydney, NSW, Australia.

Orthopaedic Research Institute, St George Hospital Campus, University of New South Wales, Sydney, NSW, Australia.

出版信息

J Shoulder Elbow Surg. 2021 Dec;30(12):e753-e764. doi: 10.1016/j.jse.2021.04.027. Epub 2021 May 5.

Abstract

BACKGROUND

Ultrasonographic imaging has been widely used as a diagnostic tool for rotator cuff tears. Several studies have explored the changes in rotator cuff tendon morphology after arthroscopic cuff repair; however, none have addressed the fate of sutures. The aim of this study was to determine (1) if the sutures migrate through the tendon during the postoperative healing period in patients who have had arthroscopic rotator cuff repair; (2) if the sutures do migrate, the time point at which it does; and (3) if the quality of the tendon, in terms of tendon stiffness, modulus of elasticity, bursal thickness, and anatomic footprint, affects suture migration.

METHODS

This was a prospective study involving 21 patients who had primary arthroscopic rotator cuff repair performed by a single surgeon. All patients were assessed at 8 days, 6 weeks, 12 weeks, and 24 weeks postrepair; during each assessment, patients underwent an ultrasonographic examination (using a Siemens ACUSON S3000 ultrasonographic system, following a standardized protocol), where supraspinatus tendon thickness and thickness of tendon tissues below and above the suture were measured. Measurements of anatomic footprint, bursal thickness, tendon stiffness, and modulus of elasticity were obtained to assess tendon quality.

RESULTS

Of the 21 participants, 14 (67%) had full-thickness tears and 7 (33%) had partial-thickness tears. Between the 12th- and 24th-week follow-up, 2 patients' tendons were found to be not intact. Within the first 12 weeks of the postrepair healing period, the sutures migrated inferiorly, through to the middle of the tendon at the footprint-articular junction (ie, ratio of tendon tissue thickness below the suture to the total tendon thickness = 0.5) (P = .03). The mean anatomic footprint increased from 8.4 ± 1.6 mm to 9.1 ± 1.2 mm between 8 days and 6 weeks (P = .04); bursal thickness decreased during the 24-week period from 1.5 ± 0.9 mm to 0.7 ± 0.4 mm (P = .005); tendon modulus of elasticity increased from 154 ± 75 kPa to 205 ± 96 kPa between 8 days and 24 weeks (P = .05).

DISCUSSION

This is the first study to investigate suture position and migration post arthroscopic rotator cuff repair. The findings of this study suggest that sutures migrating to the middle of the tendon during the postoperative healing process is a normal phenomenon observed on ultrasonography.

摘要

背景

超声成像已被广泛用作诊断肩袖撕裂的工具。多项研究探讨了关节镜下肩袖修复术后肩袖肌腱形态的变化;然而,尚无研究涉及缝线的转归情况。本研究的目的是确定:(1)在接受关节镜下肩袖修复的患者术后愈合期间,缝线是否会在肌腱内迁移;(2)如果缝线发生迁移,迁移的时间点;(3)肌腱质量,包括肌腱硬度、弹性模量、滑囊厚度和解剖足迹,是否会影响缝线迁移。

方法

这是一项前瞻性研究,纳入了21例由同一位外科医生进行初次关节镜下肩袖修复的患者。所有患者在修复后8天、6周、12周和24周接受评估;每次评估时,患者均接受超声检查(使用西门子ACUSON S3000超声系统,遵循标准化方案),测量冈上肌腱厚度以及缝线下方和上方肌腱组织的厚度。获取解剖足迹、滑囊厚度、肌腱硬度和弹性模量的测量值以评估肌腱质量。

结果

21名参与者中,14例(67%)为全层撕裂,7例(33%)为部分层撕裂。在第12周和第24周随访之间,发现2例患者的肌腱不完整。在修复后愈合期的前12周内,缝线向下迁移,直至在足迹 - 关节交界处到达肌腱中部(即缝线下方肌腱组织厚度与肌腱总厚度之比 = 0.5)(P = 0.03)。8天至6周期间,平均解剖足迹从8.4 ± 1.6 mm增加至9.1 ± 1.2 mm(P = 0.04);滑囊厚度在24周期间从1.5 ± 0.9 mm降至0.7 ± 0.4 mm(P = 0.005);肌腱弹性模量在8天至24周期间从154 ± 75 kPa增加至205 ± 96 kPa(P = 0.05)。

讨论

这是第一项研究关节镜下肩袖修复术后缝线位置和迁移情况的研究。本研究结果表明,术后愈合过程中缝线迁移至肌腱中部是超声检查中观察到的正常现象。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验