Suppr超能文献

Herbst 和 AdvanSync 矫治器治疗后咽腔气道和舌空间的头影测量评估:一项前瞻性随机临床试验。

Cephalometric evaluation of pharyngeal airway and tongue space following treatment with Herbst and AdvanSync appliances : A prospective randomized clinical trial.

机构信息

Department of Orthodontics and Dentofacial Orthopaedics, Faculty of Dental Sciences, SGT University, Gurgaon (Haryana), India.

出版信息

J Orofac Orthop. 2024 May;85(Suppl 1):7-18. doi: 10.1007/s00056-023-00449-3. Epub 2023 Feb 28.

Abstract

OBJECTIVES

To evaluate and compare pharyngeal airway and tongue space changes after treatment with fixed functional appliances-Herbst and AdvanSync™ (Ormco, Orange, CA, USA) appliances-in skeletal class II patients in pre- and posttreatment lateral cephalograms.

METHODS

For this randomized, controlled trial, 40 patients (21 male, 19 female) were divided into two groups-a Herbst group (mean age 12.6 ± 0.67 years) and an AdvanSync group (mean age 12.8 ± 0.66 years). Pre- and posttreatment (appliance therapy duration-8 months) lateral cephalograms were traced using a software program to evaluate pharyngeal airway and tongue space changes.

RESULTS

Nasopharyngeal airway, velopharyngeal airway, glossopharyngeal airway, and hypopharyngeal airway increased in the Herbst group by 2.12 mm (p ≤ 0.001), 2.33 mm (p ≤ 0.001), 2.40 mm (p ≤ 0.01), and 1.57 mm (p ≤ 0.05), while in the AdvanSync group the increases were 1.89 mm (p ≤ 0.001), 1.21 mm (p ≤ 0.001), 1.18 mm (p ≤ 0.001), and 1.53 mm (p ≤ 0.001), respectively. In the Herbst group, tongue length and height increases were 2.04 mm (p ≤ 0.01) and 3.74 mm (p ≤ 0.001), while the values in the AdvanSync group were 2.41 mm (p ≤ 0.05) and 2.69 mm (p ≤ 0.001). The change of the tongue tip from the lower occlusal plane was 0.69 mm (p ≤ 0.001) in the Herbst group and 0.77 mm (p ≤ 0.001) in the AdvanSync group. The velopharyngeal airway dimension was correlated positively with that of the retroglossal oropharyngeal airway, which in-turn positively correlated with the laryngopharyngeal airway which correlated well with the distance of the tongue tip from the lower occlusal plane.

CONCLUSIONS

The airway dimensions and tongue parameters increased significantly in both treatment groups in the present study. These changes were higher in the Herbst appliance than in the AdvanSync group, except for the distance of the tongue tip from the lower occlusal plane. A significant difference between the pharyngeal airways was found only for the retropalatal oropharyngeal airway.

摘要

目的

评估并比较使用 Herbst 和 AdvanSync™(Ormco,Orange,CA,USA)矫治器治疗后,骨性 II 类错颌患者治疗前后侧位头颅侧位片上咽腔气道和舌间隙的变化。

方法

本随机对照试验纳入 40 名患者(21 名男性,19 名女性),分为 Herbst 组(平均年龄 12.6±0.67 岁)和 AdvanSync 组(平均年龄 12.8±0.66 岁)。使用软件程序追踪治疗前(矫治器治疗时间 8 个月)和治疗后的侧位头颅侧位片,以评估咽腔气道和舌间隙的变化。

结果

Herbst 组的鼻咽气道、腭咽气道、舌后咽气道和下咽气道分别增加了 2.12mm(p≤0.001)、2.33mm(p≤0.001)、2.40mm(p≤0.01)和 1.57mm(p≤0.05),而 AdvanSync 组分别增加了 1.89mm(p≤0.001)、1.21mm(p≤0.001)、1.18mm(p≤0.001)和 1.53mm(p≤0.001)。在 Herbst 组,舌长度和高度分别增加了 2.04mm(p≤0.01)和 3.74mm(p≤0.001),而在 AdvanSync 组则分别增加了 2.41mm(p≤0.05)和 2.69mm(p≤0.001)。舌尖从下颌咬合平面向下的变化在 Herbst 组为 0.69mm(p≤0.001),在 AdvanSync 组为 0.77mm(p≤0.001)。腭后咽气道的大小与舌后咽气道呈正相关,而舌后咽气道又与喉咽气道呈正相关,与舌尖与下颌咬合平面的距离呈正相关。

结论

本研究中,两组患者的气道尺寸和舌参数均显著增加。与 AdvanSync 组相比,Herbst 矫治器组的这些变化更高,除了舌尖与下颌咬合平面的距离。仅在后咽气道中发现了咽气道之间的显著差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验