Department of Ophthalmology, Beytepe Şehit Murat Erdi Eker State Hospital, Ahlatlıbel Mh. 1746 Sk., 06800, Beytepe, Çankaya, Ankara, Turkey.
Department of Ophthalmology, Konya City Hospital, Konya, Turkey.
Int Ophthalmol. 2023 Jun;43(6):2109-2117. doi: 10.1007/s10792-023-02654-w. Epub 2023 Mar 4.
Measuring the optic nerve sheath diameter (ONSD) and the anteroposterior axial length of the eye in patients with optic disc drusen (ODD).
A total of 43 healthy volunteers and 41 patients with ODD were included in the study. The ONSD and axial length were measured in the posterior position using an ultrasound device (E-Z Scan AB5500 +) probe with a 10 MHz frequency. The ONSD was measured 3 mm behind the globe wall. Receiver operating characteristic (ROC) curve analysis was performed to determine patients with ODD using ONSD. Any p-value of < 0.05 was accepted to demonstrate significance.
The ONSD was significantly higher (5.2 mm and 4.8 mm, p = 0.006, respectively), and the axial length was shorter (21.82 ± 2.15 mm and 23.27 ± 1.96 mm, p = 0.002, respectively) in the ODD group. The spherical equivalent was more commonly seen as hypermetropic in the ODD group (1.00 [- 0.85 to 1.75]). In the ROC analysis to determine the ONSD value in ODD diagnosis, the area under the curve was 0.6754 (95% confidence interval 0.559-0.788, p = 0.006). ONSD cutoff of 5.70 mm had a sensitivity of 0.366 and a specificity of 0.907 to diagnose ODD.
In this study, the ONSD was significantly higher in the ODD group. The axial length was shorter in the ODD group. This study is the first in the literature to evaluate the ONSD in patients with optic disc drusen. Further studies are needed in this regard.
测量有视盘玻璃膜疣(ODD)的患者视神经鞘直径(ONSD)和眼球前后轴长。
本研究纳入了 43 名健康志愿者和 41 名 ODD 患者。使用频率为 10MHz 的超声设备(E-Z Scan AB5500+探头),在眼球后壁测量 ONSD 和轴向长度。ONSD 在眼球壁后 3mm 处测量。使用 ONSD 进行 ROC 曲线分析以确定 ODD 患者。任何 p 值<0.05 均被认为具有统计学意义。
ODD 组的 ONSD 明显更高(分别为 5.2mm 和 4.8mm,p=0.006),轴向长度更短(分别为 21.82±2.15mm 和 23.27±1.96mm,p=0.002)。ODD 组更常见远视性等效球镜(1.00[-0.85 至 1.75])。在 ROC 分析中,以确定 ODD 诊断中 ONSD 值,曲线下面积为 0.6754(95%置信区间 0.559-0.788,p=0.006)。ONSD 截断值为 5.70mm 时,诊断 ODD 的敏感性为 0.366,特异性为 0.907。
在这项研究中,ODD 组的 ONSD 明显更高。ODD 组的轴向长度更短。这是文献中首次评估有视盘玻璃膜疣患者的 ONSD。在这方面需要进一步的研究。