Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 10, CH-3010 Bern, Switzerland.
Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland.
Europace. 2023 Apr 15;25(4):1500-1502. doi: 10.1093/europace/euad060.
Pulsed field ablation (PFA) for pulmonary vein isolation (PVI) combines the benefits of high procedural efficacy and safety. Transseptal puncture (TSP) to obtain left atrial (LA) access during PVI remains an important source of complications during LA procedures. For PFA procedures, TSP is generally performed using a standard transseptal sheath that is then exchanged over the wire for a dedicated PFA sheath, which might be a potential source for air embolism. We aimed to prospectively evaluate the feasibility and safety of a simplified workflow using the PFA sheath (Faradrive, Boston Scientific) directly for TSP.
We prospectively enrolled 100 patients undergoing PVI using PFA at two centres. TSP was performed using the PFA sheath and a standard 98 cm transseptal needle under fluoroscopic guidance. TSP via the PFA sheath was successfully performed in all patients and no complications occurred. The median time from the first groin puncture to the completed LA access was 12 min (IQR 8-16 min).
An over-the-needle TSP directly with the PFA sheath proved feasible and safe in our study. This simplified workflow has the potential to reduce the risk of air embolism, to shorten procedure time, and to reduce cost.
脉冲场消融(PFA)用于肺静脉隔离(PVI)结合了高程序疗效和安全性的优势。在 PVI 过程中,经皮穿刺房间隔(TSP)以获得左心房(LA)进入仍然是 LA 手术过程中并发症的重要来源。对于 PFA 程序,TSP 通常使用标准的经皮穿刺鞘进行,然后通过该鞘进行线交换,以获得专用的 PFA 鞘,这可能是空气栓塞的潜在来源。我们旨在前瞻性评估使用 PFA 鞘(Faradrive,Boston Scientific)直接进行 TSP 的简化工作流程的可行性和安全性。
我们前瞻性地招募了在两个中心接受 PFA 治疗的 100 名 PVI 患者。TSP 通过在透视引导下使用 PFA 鞘和标准的 98cm 经皮穿刺针进行。所有患者均成功通过 PFA 鞘进行 TSP,无并发症发生。从首次腹股沟穿刺到完成 LA 进入的中位数时间为 12 分钟(IQR 8-16 分钟)。
在我们的研究中,直接使用 PFA 鞘进行经皮穿刺房间隔证明是可行和安全的。这种简化的工作流程有可能降低空气栓塞的风险,缩短手术时间,降低成本。