Medical device-related pressure ulcer (MDRPU) is a skin or subcutaneous tissue injury caused by medical devices. Skin protectants have been used to prevent MDRPU in other fields. In endoscopic sinonasal surgery (ESNS), rigid endoscopes and forceps can cause MDRPU; however, detailed investigations have not been conducted. This study aimed to investigate the frequency of MDRPU in ESNS and the preventive effects of skin protectants METHODS: Thirty-nine patients who received ESNS and consented to study participation were randomly assigned to the "protective agent" (n = 18) or "control" (n = 21) group. MDRPU presence around the nostril was evaluated for up to 7 days post-surgically based on physical findings and subjective symptoms. The occurrence ratio and severity of MDRPU were statistically compared between the groups to evaluate the efficacy of skin protective agents.
Stage 1 MDRPU, according to the National Pressure Ulcer Advisory Panel classification, was seen in 20.5% (8/39) of the patients, and no patient had more high-grade ulceration. On postoperative days 2 and 3, skin erythema was predominantly observed on the nasal floor, with a comparatively lower incidence in the protective agent group. Significant pain reduction was observed in the nostril's floor on postoperative days 2 and 3 in the protective agent group.
MDRPU occurred with a relatively high frequency around the nostrils after ESNS. Protective agent use in the external nostrils was effective especially in reducing post-operative pain on the nasal floor, where tissue damage can easily occur due to device-related friction.
医疗器械相关性压疮(MDRPU)是由医疗器械引起的皮肤或皮下组织损伤。皮肤保护剂已被用于预防其他领域的 MDRPU。在内镜鼻窦手术(ESNS)中,硬性内窥镜和器械钳可导致 MDRPU,但尚未进行详细研究。本研究旨在调查 ESNS 中 MDRPU 的发生频率以及皮肤保护剂的预防效果。
39 名接受 ESNS 并同意参与研究的患者被随机分配到“保护剂”(n=18)或“对照组”(n=21)。根据体格检查和主观症状,术后最多 7 天评估鼻旁 MDRPU 的存在情况。通过比较组间 MDRPU 的发生比率和严重程度,评估皮肤保护剂的疗效。
根据国家压疮咨询小组分类,有 20.5%(39 例中的 8 例)的患者出现 1 期 MDRPU,且无患者发生更高级别的溃疡。术后第 2 和第 3 天,主要观察到鼻底皮肤红斑,保护剂组的发生率较低。在保护剂组,术后第 2 和第 3 天,鼻底的疼痛明显减轻。
ESNS 后鼻旁周围发生 MDRPU 的频率相对较高。在外鼻孔使用保护剂,特别是在外鼻孔使用保护剂,特别有效,可以减少因器械相关摩擦而导致的组织损伤的术后疼痛。