Department of Urology, Bordeaux University Hospital, Bordeaux, France.
Department of Urology, Bordeaux University Hospital, Bordeaux, France.
Urology. 2023 Jun;176:36-41. doi: 10.1016/j.urology.2023.02.039. Epub 2023 Mar 11.
To create and assess the validity of a high-fidelity, three dimensional (3D) printed, flexible ureteroscopy simulator resulting from a real case.
A patient's CT scan was segmented to obtain a 3D model in .stl format, including the urinary bladder, ureter and renal cavities. The file was printed and a kidney stone was introduced into the cavities. The simulated surgery consisted of monobloc stone extraction. Nineteen participants split into 3 groups according to their level (6 medical students, 7 residents and 6 urology fellows) performed the procedure twice at a 1-month interval. They were rated according to a global score and a task-specific score, based on an anonymized, timed video recording.
Participants demonstrated a significant improvement between the 2 assessments, both on the global score (29.4 vs 21.9 points out of 35; P < .001) and the task-specific score (17.7 vs 14.7 points out of 20; P < .001) as well as procedure time (498.5 vs 700 seconds; P = .001). Medical students showed the greatest progress for the global score (+15.5 points (mean), P = .001) and the task-specific score (+6.5 points (mean), P < .001). 69.2% of participants considered the model as visually quite realistic or highly realistic and all of them judged it quite or extremely interesting for intern training purposes.
Our 3D printed ureteroscopy simulator was able to enhance the progress of medical students who are new to endoscopy, whilst being valid and reasonably priced. It could become part of a training program in urology, in line with the latest recommendations for surgical education.
创建并评估源自真实病例的高保真、三维(3D)打印、柔性输尿管镜模拟器的有效性。
对患者的 CT 扫描进行分割,以获得以.stl 格式表示的 3D 模型,包括膀胱、输尿管和肾腔。打印文件,并将肾结石引入腔中。模拟手术包括整体结石提取。19 名参与者根据其水平(6 名医学生、7 名住院医师和 6 名泌尿科医师)分为 3 组,在 1 个月的间隔内进行两次手术。根据匿名、计时的视频记录,根据总体评分和特定任务评分对他们进行评分。
参与者在两次评估中均表现出显著改善,总体评分(35 分中得分为 29.4 分与 21.9 分;P <.001)和特定任务评分(20 分中得分为 17.7 分与 14.7 分;P <.001)以及手术时间(498.5 秒与 700 秒;P =.001)均有所改善。医学生在总体评分(增加 15.5 分(平均值),P =.001)和特定任务评分(增加 6.5 分(平均值),P <.001)方面取得了最大的进步。69.2%的参与者认为模型在视觉上非常逼真或高度逼真,并且他们都认为该模型对于实习医生培训非常有趣。
我们的 3D 打印输尿管镜模拟器能够提高对内镜检查不熟悉的医学生的进步,同时具有有效性和合理的价格。它可以成为泌尿科培训计划的一部分,符合最新的手术教育建议。