Ventricular septal defects (VSDs) are the most common kind of congenital heart disease and, if indicated, surgical closure has been accepted as a gold-standard treatment. However, as less-invasive methods are preferred, percutaneous device closure has been developed. After the first VSD closure was performed percutaneously by Lock in 1988, both techniques and devices have developed consistently. A perventricular approach for closure of muscular VSD in small patients and the closure of perimembranous VSD using off-label devices are key remarkable developments. Even though the Amplatzer membranous VSD occluder (Abbott) could not be approved for use due to the high complete atrioventricular conduction block rate, other new devices have shown good results for closure of perimembranous VSDs. However, the transcatheter technique is slightly complicated to perform, and concerns about conduction problems after VSD closure with devices remain. There have been a few reports demonstrating successful closure of subarterial-type VSDs with Amplatzer devices, but long-term issues involving aortic valve damage have not been explored yet. In conclusion, transcatheter VSD closure should be accepted as being as effective and safe as surgery but should only be performed by experienced persons and in specialized institutes because the procedure is complex and requires different techniques. To avoid serious complications, identifying appropriate patient candidates for device closure before the procedure is very important.

摘要

室间隔缺损(VSDs)是最常见的先天性心脏病类型,若有指征,手术闭合已被公认为金标准治疗方法。然而,由于更微创的方法更受青睐,经皮器械闭合术应运而生。1988年洛克首次经皮进行室间隔缺损闭合术后,技术和器械都不断发展。针对小患者的肌部室间隔缺损采用经心室途径闭合,以及使用未获批准的器械闭合膜周部室间隔缺损,都是显著的关键进展。尽管由于高完全性房室传导阻滞发生率,Amplatzer膜周部室间隔缺损封堵器(雅培公司)未获批准使用,但其他新器械在闭合膜周部室间隔缺损方面已显示出良好效果。然而,经导管技术操作稍复杂,且使用器械闭合室间隔缺损后对传导问题仍存担忧。有一些报告显示使用Amplatzer器械成功闭合动脉下型室间隔缺损,但涉及主动脉瓣损伤的长期问题尚未探讨。总之,经导管室间隔缺损闭合术应被视为与手术一样有效和安全,但仅应由经验丰富的人员在专业机构进行,因为该操作复杂且需要不同技术。为避免严重并发症,术前识别适合器械闭合的患者候选人非常重要。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5642/10011220/f5faec0face1/kcj-53-134-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验