Vorster Martin, Gravett Dewald Zane, van der Vyver Peet J, Markou George
Department of Odontology, School of Dentistry, Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa.
Department of Civil Engineering, University of Pretoria, Pretoria, South Africa.
J Endod. 2023 May;49(5):559-566. doi: 10.1016/j.joen.2023.03.004. Epub 2023 Mar 15.
This study evaluated the effect of traditional and conservative endodontic access cavity designs in combination with WaveOne Gold and TruNatomy instrumentation systems on the fracture resistance of mandibular first molars by means of nonlinear finite element analysis (FEA).
Micro-CT images of 4 human mandibular first molars were used to generate representative FEA models. The mandibular first molars samples were scanned before and after endodontic access cavity preparation and instrumentation of all 3 canals. Five nonlinear static loads were applied vertically and horizontally to specific contact points on the occlusal surface of the teeth. Maximum von Mises stress before failure and distribution of von Mises strains were recorded and compared between groups.
Molars with conservative endodontic access cavities required similar levels of loads to reach failure compared with their control samples, whereas molars with traditional endodontic access cavities required significantly reduced loads in order to fail. According to the numerical investigation, the type of instrumentation system was found to have an insignificant effect on the fracture resistance of the teeth under study. Von Mises stress was concentrated around the cervical region and in the larger distal roots for all numerical models.
The fracture resistance of mandibular first molars is influenced significantly by a reduction in dental hard tissue, which was found to control the level of the ultimate failure load for each tooth.
本研究通过非线性有限元分析(FEA),评估了传统和保守的牙髓治疗开髓腔设计与WaveOne Gold和TruNatomy根管预备系统相结合对下颌第一磨牙抗折性能的影响。
使用4颗人类下颌第一磨牙的显微CT图像生成具有代表性的有限元分析模型。在所有3个根管进行牙髓治疗开髓腔预备和根管预备前后,对下颌第一磨牙样本进行扫描。在牙齿咬合面的特定接触点垂直和水平施加5种非线性静载荷。记录并比较各组失效前的最大冯·米塞斯应力和冯·米塞斯应变分布。
与对照样本相比,采用保守牙髓治疗开髓腔的磨牙达到失效所需的载荷水平相似,而采用传统牙髓治疗开髓腔的磨牙达到失效所需的载荷显著降低。根据数值研究,发现所研究的根管预备系统类型对牙齿的抗折性能影响不显著。在所有数值模型中,冯·米塞斯应力集中在颈部区域和较大的远中根。
下颌第一磨牙的抗折性能受牙体硬组织减少的显著影响,牙体硬组织减少控制着每颗牙齿的最终失效载荷水平。