Suppr超能文献

可控腔内压力的软性输尿管镜鞘在输尿管结石治疗中的临床应用

Clinical application of flexible ureteroscopic sheath with controllable intraluminal pressure in treating ureteral stones.

作者信息

Zhong Yuming, Xie Donghua, Luo Chunxiang, Liao Xiaohui, Liu Tairong, Deng Xiaoling, Zhu Lunfeng, Song Leming

机构信息

Department of Urology, The Affiliated Ganzhou Hospital of Nanchang University, Ganzhou, Jiangxi, China.

Xie Urology, Margate, FL, USA.

出版信息

Asian J Urol. 2023 Apr;10(2):166-171. doi: 10.1016/j.ajur.2021.08.007. Epub 2021 Aug 26.

Abstract

OBJECTIVE

The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure the ureteropelvic pressure in implementing lithotripsies.

METHODS

Fifty-two patients who underwent lithotripsy under intelligent monitoring of ureteral intraluminal pressure from June 2016 to January 2018 were retrospectively recruited. The inclusion standard was stone diameter >1.5 cm but <2.5 cm. After the 12/14 Fr suction sheath was placed, manometer interface and suction interface of the sheath were connected to the platform via the pressure sensor and suction tube, respectively. The ureteroscope was connected to the platform perfusion pump, and the crushed stones were aspirated out under negative pressure.

RESULTS

According to the location of the stone, 21 (40.4%) cases were classified as upper ureteral stones, 19 (36.5%) were midureteral stones, and 12 (23.1%) were lower ureteral stones. Forty-seven patients underwent successful primary sheath placement and lithotripsy with a mean operative time of 34.5 (standard deviation 18.3) min. Retrograde stone migration did not occur. There were eight patients with hematuria postoperatively. Serious complication was 1.9% with one case of ureteral perforation. Stone clearance was 95.7% at Day 1-2 postoperatively, and 100% at Day 30 postoperatively.

CONCLUSION

Ureteroscopic lithotripsy with intelligent pressure control using our device improved the efficiency of the lithotripsy and rate of stone clearance. The safety of the operation can be ensured. It is worth popularization and application in clinical practice.

摘要

目的

本研究旨在评估一种具有压力反馈控制功能的联合灌注吸引平台以及一种可测量肾盂输尿管压力的输尿管镜吸引鞘在实施碎石术中的临床疗效和安全性。

方法

回顾性纳入2016年6月至2018年1月期间在输尿管腔内压力智能监测下接受碎石术的52例患者。纳入标准为结石直径>1.5 cm但<2.5 cm。放置12/14 Fr吸引鞘后,鞘的压力计接口和吸引接口分别通过压力传感器和吸引管连接至平台。输尿管镜连接至平台灌注泵,碎石在负压下吸出。

结果

根据结石位置,21例(40.4%)为输尿管上段结石,19例(36.5%)为输尿管中段结石,12例(23.1%)为输尿管下段结石。47例患者成功进行了初次鞘置入和碎石术,平均手术时间为34.5(标准差18.3)分钟。未发生结石逆行移位。术后有8例患者出现血尿。严重并发症发生率为1.9%,有1例输尿管穿孔。术后第1 - 2天结石清除率为95.7%,术后第30天为100%。

结论

使用我们的设备进行智能压力控制的输尿管镜碎石术提高了碎石效率和结石清除率。可确保手术安全。值得在临床实践中推广应用。