Suppr超能文献

“缺损覆盖指数法”是一种用于关节镜下骨块手术矢状面移植物定位的新型计算机断层扫描评估方法,对其观察者间和观察者内的可重复性进行评估。

Evaluation of the inter and intraobserver reproducibility of the "defect coverage index method", a new computed tomography assessment method of sagittal graft positioning in arthroscopic bone block procedures.

作者信息

Delgado Cristina, De Rus Ignacio, Cañete Pablo, Díaz Jorge, Ruiz Raquel, García Navlet Miguel, Ruiz Ibán Miguel Ángel

机构信息

Hospital Universitario Fundación Jiménez Díaz, Madrid, Spain.

Hospital Universitario Torrejón, Madrid, Spain.

出版信息

J Exp Orthop. 2023 Mar 30;10(1):35. doi: 10.1186/s40634-023-00590-3.

Abstract

PURPOSE

To assess the reproducibility of a new 2-dimensional computed tomography (CT) method of assessing graft positioning in arthroscopic bone block procedure.

METHODS

This is a prospective observational study. Twenty-seven patients, (all men, mean [Standard deviation] age at surgery 30.9 [8.49] years) were included. Vertical graft position was assessed on the sagittal view by measuring the amount of glenoid bone defect covered by the graft. The length of the bone defect and the amount of graft covering the defect were measured. Positioning of the graft on the sagittal plane was classified as accurate if the graft covered at least 90% of the defect. Intraobserver and interobserver reproducibility was analyzed using intraclass correlation coefficients (ICC) and Kappa coefficient with 95% confidence.

RESULTS

Excellent intraobserver reproducibility was found, with an ICC of 0.94 (CI 95%, 0.86-0.97). Interobserver reproducibility was good, with the ICC value of 0.71, ranging from 0.45 to 0.86 (CI 95%).

CONCLUSION

This new method of assessing graft positioning in arthroscopic bone block procedures on 2-dimensional computed tomography scans is reliable, with an excellent intraobserver and good interobserver reproducibility.

LEVEL OF EVIDENCE

III.

摘要

目的

评估一种用于在关节镜下骨块手术中评估移植物位置的新型二维计算机断层扫描(CT)方法的可重复性。

方法

这是一项前瞻性观察性研究。纳入了27例患者(均为男性,手术时平均[标准差]年龄30.9[8.49]岁)。通过测量移植物覆盖的肩胛盂骨缺损量在矢状面上评估移植物的垂直位置。测量骨缺损的长度和移植物覆盖缺损的量。如果移植物覆盖至少90%的缺损,则将移植物在矢状面上的定位分类为准确。使用组内相关系数(ICC)和95%置信度的Kappa系数分析观察者内和观察者间的可重复性。

结果

发现观察者内具有出色的可重复性,ICC为0.94(95%CI,0.86 - 0.97)。观察者间的可重复性良好,ICC值为0.71,范围为0.45至0.86(95%CI)。

结论

这种在二维计算机断层扫描上评估关节镜下骨块手术中移植物位置的新方法是可靠的,具有出色的观察者内和良好的观察者间可重复性。

证据级别

III级。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/836d/10063754/34b75841ba82/40634_2023_590_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验