This paper gives a comprehensive progress report on the development of objective methods for measuring the attenuation of hearing protection devices (HPD's), and focuses on the use of acoustic test fixtures (ATF's), i.e., artificial heads. While there are many publications on ATF's for the evaluation of circumaural HPD's (earmuffs), only one serious attempt to construct an ATF for the evaluation of intra-aural HPD's (earplugs) could be found. Consequently, no ATF for testing earplugs has been standardized so far, while two standardized ATF's currently exist for testing earmuffs [see ANSI S3.19-1974 (1975) and ISO/DIS 6290 (1983)]. Both ATF's are suited, however, only for production testing and are not designed for HPD-type testing. It is believed that both ATF's do not provide sufficiently high accuracy for HPD-type testing. A new ATF with appropriate circumaural and intra-aural flesh simulations was constructed, including a suitable ear simulator and a cast of an average pinna. Objectives for design and construction of the new ATF are discussed. The effect of using artificial flesh on the insertion loss of earmuffs (max. 5 dB at 125 and/or 250 Hz) and the effect of using a pinna (max. 12 dB lower insertion loss at 2 kHz) were evaluated.
本文给出了关于测量听力保护装置(HPD)衰减的客观方法发展的全面进展报告,并着重介绍了声学测试夹具(ATF)即人工头的使用。虽然有许多关于用于评估耳罩式HPD(耳罩)的ATF的出版物,但仅发现一次构建用于评估耳塞式HPD(耳塞)的ATF的认真尝试。因此,目前还没有用于测试耳塞的ATF被标准化,而目前有两种标准化的ATF用于测试耳罩[见ANSI S3.19 - 1974(1975)和ISO/DIS 6290(1983)]。然而,这两种ATF都仅适用于生产测试,并非为HPD类型测试而设计。据信,这两种ATF对于HPD类型测试都没有提供足够高的精度。构建了一种具有合适的耳罩式和耳塞式肉模拟的新型ATF,包括一个合适的耳朵模拟器和一个平均耳廓模型。讨论了新型ATF设计和构建的目标。评估了使用人工肉对耳罩插入损耗的影响(在125和/或250Hz时最大为5dB)以及使用耳廓对插入损耗的影响(在2kHz时插入损耗降低最大为12dB)。