Department of Radiology, University of Wisconsin, Madison, WI, USA.
Section of Vascular Surgery, Department of Surgery, University of Michigan, Ann Arbor, MI, USA.
Abdom Radiol (NY). 2023 Jun;48(6):2049-2059. doi: 10.1007/s00261-023-03892-3. Epub 2023 Apr 4.
The purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects.
For this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after ≥ 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean ± 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance.
We included 44 healthy subjects (26 female, 18-74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow (34%). Conservation of mass analysis demonstrated a relative error of 1.1 ± 4.6% standard deviation (SD) at the splenomesenteric confluence and - 1.4 ± 4.1% SD at the portal bifurcation.
We have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts.
本研究旨在建立 4D 流 MRI 衍生的血流、速度和血管直径的正常参考值,并确定健康成年受试者门静脉系统的特征性血流模式。
本回顾性研究筛选了 2012 年至 2022 年在我院行上腹部 4D 流 MRI 检查的所有健康成年人的资料,这些患者在禁食≥5 小时后于 1.5T 或 3.0T MRI 上进行检查。在门静脉系统的 8 个层面(脾静脉、肠系膜上静脉、主门静脉、右门静脉和左门静脉)定量测量血流、速度和有效直径。随着时间的推移,手动调整血管轮廓。定义参考范围为平均值±2 个标准差。3 位读者在时间分辨路径可视化上记录螺旋和涡旋血流。进行质量保证的质量守恒流分析。
我们共纳入 44 名健康受试者(26 名女性,18-74 岁)进行分析。我们使用 4D 流 MRI 报告门静脉正常血流的平均和峰值流量、平均速度和血管直径的参考值。门静脉的正常血流模式包括微弱的螺旋(66%)或线性(34%)。质量守恒分析显示在脾肠系膜汇合处的相对误差为 1.1±4.6%标准差(SD),在门静脉分叉处为-1.4±4.1% SD。
我们报告了正常的血流动力学值,这是门静脉系统 4D 流 MRI 新兴临床应用的必要基线数据。结果与先前发表的较小队列的数值一致。