门静脉系统 4D 流磁共振成像的参考值。

Reference values for 4D flow magnetic resonance imaging of the portal venous system.

机构信息

Department of Radiology, University of Wisconsin, Madison, WI, USA.

Section of Vascular Surgery, Department of Surgery, University of Michigan, Ann Arbor, MI, USA.

出版信息

Abdom Radiol (NY). 2023 Jun;48(6):2049-2059. doi: 10.1007/s00261-023-03892-3. Epub 2023 Apr 4.

Abstract

PURPOSE

The purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects.

METHODS

For this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after ≥ 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean ± 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance.

RESULTS

We included 44 healthy subjects (26 female, 18-74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow (34%). Conservation of mass analysis demonstrated a relative error of 1.1 ± 4.6% standard deviation (SD) at the splenomesenteric confluence and - 1.4 ± 4.1% SD at the portal bifurcation.

CONCLUSION

We have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts.

摘要

目的

本研究旨在建立 4D 流 MRI 衍生的血流、速度和血管直径的正常参考值,并确定健康成年受试者门静脉系统的特征性血流模式。

方法

本回顾性研究筛选了 2012 年至 2022 年在我院行上腹部 4D 流 MRI 检查的所有健康成年人的资料,这些患者在禁食≥5 小时后于 1.5T 或 3.0T MRI 上进行检查。在门静脉系统的 8 个层面(脾静脉、肠系膜上静脉、主门静脉、右门静脉和左门静脉)定量测量血流、速度和有效直径。随着时间的推移,手动调整血管轮廓。定义参考范围为平均值±2 个标准差。3 位读者在时间分辨路径可视化上记录螺旋和涡旋血流。进行质量保证的质量守恒流分析。

结果

我们共纳入 44 名健康受试者(26 名女性,18-74 岁)进行分析。我们使用 4D 流 MRI 报告门静脉正常血流的平均和峰值流量、平均速度和血管直径的参考值。门静脉的正常血流模式包括微弱的螺旋(66%)或线性(34%)。质量守恒分析显示在脾肠系膜汇合处的相对误差为 1.1±4.6%标准差(SD),在门静脉分叉处为-1.4±4.1% SD。

结论

我们报告了正常的血流动力学值,这是门静脉系统 4D 流 MRI 新兴临床应用的必要基线数据。结果与先前发表的较小队列的数值一致。

相似文献

1
Reference values for 4D flow magnetic resonance imaging of the portal venous system.
Abdom Radiol (NY). 2023 Jun;48(6):2049-2059. doi: 10.1007/s00261-023-03892-3. Epub 2023 Apr 4.
2
4D flow MR imaging of the portal venous system: a feasibility study in children.
Eur Radiol. 2017 Feb;27(2):832-840. doi: 10.1007/s00330-016-4396-1. Epub 2016 May 18.
3
Clinical Applications of 4D Flow MRI in the Portal Venous System.
Magn Reson Med Sci. 2022 Mar 1;21(2):340-353. doi: 10.2463/mrms.rev.2021-0105. Epub 2022 Jan 25.
4
Impaired regulation of portal venous flow in response to a meal challenge as quantified by 4D flow MRI.
J Magn Reson Imaging. 2015 Oct;42(4):1009-17. doi: 10.1002/jmri.24886. Epub 2015 Mar 16.
5
6
4D Flow MRI in the portal venous system: imaging and analysis methods, and clinical applications.
Radiol Med. 2022 Nov;127(11):1181-1198. doi: 10.1007/s11547-022-01553-x. Epub 2022 Sep 19.
7
Hemodynamic changes in the portal vein with age: evaluation using four-dimensional flow MRI.
Sci Rep. 2023 May 6;13(1):7397. doi: 10.1038/s41598-023-34522-z.

引用本文的文献

1
Multiscale modeling of drug-induced liver injury from organ to lobule.
NPJ Digit Med. 2025 Jun 23;8(1):383. doi: 10.1038/s41746-025-01736-6.
2
Magnetic resonance imaging findings in autoimmune hepatitis: how frequent and reproducible are they?
Radiol Bras. 2023 Nov-Dec;56(6):308-316. doi: 10.1590/0100-3984.2023.0044.

本文引用的文献

1
Characterization of mesenteric and portal hemodynamics using 4D flow MRI: the effects of meals and diurnal variation.
Abdom Radiol (NY). 2022 Jun;47(6):2106-2114. doi: 10.1007/s00261-022-03513-5. Epub 2022 Apr 13.
2
Clinical Applications of 4D Flow MRI in the Portal Venous System.
Magn Reson Med Sci. 2022 Mar 1;21(2):340-353. doi: 10.2463/mrms.rev.2021-0105. Epub 2022 Jan 25.
3
Quantification of the Hemodynamic Changes of Cirrhosis with Free-Breathing Self-Navigated MRI.
J Magn Reson Imaging. 2021 May;53(5):1410-1421. doi: 10.1002/jmri.27488. Epub 2021 Feb 16.
4
Non-invasive assessment of mesenteric hemodynamics in patients with suspected chronic mesenteric ischemia using 4D flow MRI.
Abdom Radiol (NY). 2022 May;47(5):1684-1698. doi: 10.1007/s00261-020-02900-0. Epub 2021 Feb 6.
7
MRI-based modeling of spleno-mesenteric confluence flow.
J Biomech. 2019 May 9;88:95-103. doi: 10.1016/j.jbiomech.2019.03.025. Epub 2019 Mar 23.
8
The Feasibility of Using Volumetric Phase-Contrast MR Imaging (4D Flow) to Assess for Transjugular Intrahepatic Portosystemic Shunt Dysfunction.
J Vasc Interv Radiol. 2018 Dec;29(12):1717-1724. doi: 10.1016/j.jvir.2018.07.022. Epub 2018 Nov 3.
9
Four-dimensional Flow MRI as a Marker for Risk Stratification of Gastroesophageal Varices in Patients with Liver Cirrhosis.
Radiology. 2019 Jan;290(1):101-107. doi: 10.1148/radiol.2018180230. Epub 2018 Oct 16.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验