Department of Medical Imaging, Ann and Robert H. Lurie Children's Hospital of Chicago, 225 E. Chicago Ave., Chicago, IL, 60611, USA.
Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.
Eur Radiol. 2017 Feb;27(2):832-840. doi: 10.1007/s00330-016-4396-1. Epub 2016 May 18.
To determine the feasibility of 4D flow MRI for visualization and quantification of the portal venous haemodynamics in children and young adults.
4D flow was performed in 28 paediatric patients (median age, 8.5 years; interquartile range, 5.2-16.5), 15 with non-operated native portal system and 13 with surgically created portal shunt. Image quality assessment for 3D flow visualization and flow pattern analyses was performed. Regional 4D flow peak velocity and net flow were compared with 2D-cine phase contrast MRI (2D-PC MR) in the post-surgical patients.
Mean 3D flow visualization quality score was excellent (mean ± SD, 4.2 ± 0.9) with good inter-rater agreement (κ,0.67). Image quality in children aged >10 years was better than children ≤10 years (p < 0.05). Flow pattern was defined for portal, superior mesenteric, splenic veins and splenic artery in all patients. 4D flow and 2D-PC MR peak velocity and net flow were similar with good correlation (peak velocity: 4D flow 22.2 ± 9.1 cm/s and 2D-PC MR 25.2 ± 11.2 cm/s, p = 0.46; r = 0.92, p < 0.0001; net flow: 4D flow 9.5 ± 7.4 ml/s and 2D-PC MR 10.1 ± 7.3 ml/s, p = 0.65; r = 0.81, p = 0.0007).
4D flow MRI is feasible and holds promise for the comprehensive 3D visualization and quantification of portal venous flow dynamics in children and young adults.
• 4D flow MRI is feasible in children and young adults. • 4D flow MRI has the ability to non-invasively characterize portal haemodynamics. • Image quality of 4D flow MRI is better is older children. • 4D flow MRI can accurately quantify portal flow compared to 2D-cine PC MRI.
确定 4D 流 MRI 用于可视化和量化儿童和青少年门静脉血流动力学的可行性。
对 28 例儿科患者(中位年龄 8.5 岁;四分位距 5.2-16.5)进行了 4D 流检查,其中 15 例为未行手术的原发性门静脉系统,13 例为手术创建的门体分流。对 3D 流量可视化和流量模式分析进行了图像质量评估。在术后患者中,将区域性 4D 流峰值速度和净流量与 2D 电影相位对比 MRI(2D-PC MR)进行了比较。
平均 3D 流量可视化质量评分优异(平均±标准差,4.2±0.9),具有良好的观察者间一致性(κ,0.67)。年龄大于 10 岁的儿童的图像质量优于年龄等于或小于 10 岁的儿童(p<0.05)。所有患者均定义了门静脉、肠系膜上静脉、脾静脉和脾动脉的血流模式。4D 流和 2D-PC MR 峰值速度和净流量相似,相关性良好(峰值速度:4D 流 22.2±9.1cm/s 和 2D-PC MR 25.2±11.2cm/s,p=0.46;r=0.92,p<0.0001;净流量:4D 流 9.5±7.4ml/s 和 2D-PC MR 10.1±7.3ml/s,p=0.65;r=0.81,p=0.0007)。
4D 流 MRI 是可行的,有望用于儿童和青少年门静脉血流动力学的全面 3D 可视化和量化。
4D 流 MRI 在儿童和青少年中是可行的。
4D 流 MRI 具有非侵入性地描绘门静脉血流动力学的能力。
4D 流 MRI 的图像质量在较大的儿童中更好。
4D 流 MRI 可以比 2D 电影 PC MRI 更准确地定量门静脉流量。