Orthopedic Biomechanics Laboratory, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
Department of Orthopedics, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
Ann Biomed Eng. 2023 Aug;51(8):1795-1801. doi: 10.1007/s10439-023-03188-z. Epub 2023 Apr 19.
Ulnar collateral ligament reconstruction (UCLR) is frequently performed among injured overhead-throwing athletes. One of the most common graft choices when performing a UCLR is the ipsilateral palmaris longus tendon (PL). The purpose of this study was to investigate the material properties of aseptically processed cadaveric knee collateral ligaments (kMCL) as a potential graft source for UCLR and compare them to the gold standard PL autograft. Each PL and kMCL cadaveric sample was subjected to cyclic preconditioning, stress relaxation, and load-to-failure testing, and the mechanical properties were recorded. PL samples exhibited a greater average decrease in stress compared to the kMCL samples during the stress-relaxation test (p < 0.0001). PL samples also demonstrated a greater average Young's modulus in the linear region of the stress-strain curve compared to the kMCL samples (p < 0.01). The average yield strain and maximum strain of kMCL samples were significantly greater than the PL, p = 0.03 and 0.02, respectively. Both graft materials had comparable maximum toughness and demonstrated a similar ability to deform plastically without rupture. The clinical significance of our result is that prepared knee medial collateral ligament allografts may provide a viable graft material for use in the reconstruction of elbow ligaments.
尺侧副韧带重建(UCLR)在受伤的上肢投掷运动员中经常进行。在进行 UCLR 时,最常用的移植物选择之一是同侧掌长肌腱(PL)。本研究旨在研究无菌处理的尸体膝关节侧副韧带(kMCL)作为 UCLR 潜在移植物来源的材料特性,并将其与金标准 PL 自体移植物进行比较。每个 PL 和 kMCL 尸体样本都进行了循环预适应、应力松弛和失效测试,并记录了机械性能。与 kMCL 样本相比,PL 样本在应力松弛测试中表现出更大的平均应力下降(p < 0.0001)。与 kMCL 样本相比,PL 样本在应力-应变曲线的线性区域表现出更大的平均杨氏模量(p < 0.01)。kMCL 样本的平均屈服应变和最大应变明显大于 PL,p = 0.03 和 0.02。两种移植物材料的最大韧性相当,都具有类似的塑性变形能力而不会破裂。我们研究结果的临床意义是,准备好的膝关节内侧副韧带同种异体移植物可能为重建肘部韧带提供一种可行的移植物材料。