Health Hazards Prevention Branch, Pittsburgh Mining Research Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Pittsburgh, Pennsylvania.
Mining Systems Safety Branch, Pittsburgh Mining Research Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Pittsburgh, Pennsylvania.
J Occup Environ Hyg. 2023 Jul;20(7):289-303. doi: 10.1080/15459624.2023.2205448. Epub 2023 Jun 15.
The objective of this study is to evaluate a prototype local ventilation system (LVS) intended to reduce retail store workers' exposure to aerosols. The evaluation was carried out in a large aerosol test chamber where relatively uniform concentrations of polydisperse sodium chloride and glass-sphere particles were generated to test the system with nano- and micro-size particles. In addition, a cough simulator was constructed to mimic aerosols released by mouth breathing and coughing. Particle reduction efficiencies of the LVS were determined in four different experimental conditions using direct reading instruments and inhalable samplers. The particle reduction efficiency (%) depended on the position beneath the LVS, but the percentage was consistently high at the LVS center as follows: (1) > 98% particle reduction relative to background aerosols; (2) > 97% in the manikin's breathing zone relative to background aerosols; (3) > 97% during mouth breathing and coughing simulation; and (4) > 97% with a plexiglass barrier installation. Lower particle reduction (<70%) was observed when the LVS airflow was disturbed by background ventilation airflow. The lowest particle reduction (<20%) was observed when the manikin was closest to the simulator during coughing.
本研究旨在评估一种旨在减少零售商店工人气溶胶暴露的局部通风系统(LVS)原型。该评估是在一个大型气溶胶测试室中进行的,在该测试室中产生了相对均匀的多分散氯化钠和玻璃球颗粒浓度,以用纳米和微尺寸颗粒测试该系统。此外,还构建了一个咳嗽模拟器来模拟口呼吸和咳嗽释放的气溶胶。使用直读仪器和可吸入采样器,在四种不同的实验条件下确定了 LVS 的颗粒减少效率(%)。颗粒减少效率(%)取决于 LVS 下方的位置,但 LVS 中心的百分比始终很高,具体如下:(1)与背景气溶胶相比,减少 98%以上的颗粒;(2)相对于背景气溶胶,在模拟人呼吸区减少 97%以上;(3)在口呼吸和咳嗽模拟期间减少 97%以上;(4)安装有机玻璃屏障时减少 97%以上。当 LVS 气流受到背景通风气流干扰时,颗粒减少率降低(<70%)。当模拟人在咳嗽时最接近模拟器时,观察到的颗粒减少率最低(<20%)。