: Supraglottic airway devices (SADs) are known to be useful in eliminating the drawbacks of laryngoscopy and tracheal intubation, especially ocular pressure and stress responses. The ultrasonographic measurement of optic nerve sheath diameter (ONSD) reflects increases in intracranial pressure (ICP). In our study, we aimed to compare the effects of SADs on hemodynamic response and ONSD. : Our prospective study included 90 ASA I-II patients over the age of 18 who did not have a history of difficult intubation or ophthalmic pathology. The patients were randomly divided into three groups based on the laryngeal mask airway (LMA) devices used: ProSeal LMA (pLMA, = 30), LMA Supreme (sLMA, = 30), and I-gel ( = 30). The bilateral ONSD measurements and hemodynamic data of the patients who underwent standard anesthesia induction and monitoring were recorded before induction (T0) and 1 min (T1), 5 min (T5), and 10 min (T10) after SAD placement. : At all measurement times, the hemodynamic responses and ONSD values of the groups were similar. In all three groups, intergroup hemodynamic changes at T0 and T1 were similar and higher than those at other times of measurement ( < 0.001). The ONSD values of all groups increased at T1, and they tended to return to baseline values afterward ( < 0.001). : We concluded that all three SADs could be used safely because they preserved both hemodynamic stability and ONSD changes in their placement processes, and they did not cause elevations in ONSD to an extent that would lead to increased ICP.

摘要

: 声门上气道装置 (SAD) 被认为可消除喉镜和气管插管的缺点,尤其是眼内压和应激反应。视神经鞘直径 (ONSD) 的超声测量反映了颅内压 (ICP) 的增加。在我们的研究中,我们旨在比较 SAD 对血流动力学反应和 ONSD 的影响。 : 我们的前瞻性研究包括 90 名 ASA I-II 级、年龄在 18 岁以上、无困难插管史或眼部病理学史的患者。根据使用的喉罩气道 (LMA) 装置,患者随机分为三组:ProSeal LMA (pLMA,n = 30)、LMA Supreme (sLMA,n = 30) 和 I-gel (n = 30)。在标准麻醉诱导和监测下,记录接受麻醉诱导前 (T0) 和 SAD 放置后 1 分钟 (T1)、5 分钟 (T5) 和 10 分钟 (T10) 的患者双侧 ONSD 测量值和血流动力学数据。 : 在所有测量时间,各组的血流动力学反应和 ONSD 值均相似。在所有三组中,T0 和 T1 时的组间血流动力学变化相似且高于其他测量时间 ( < 0.001)。所有三组的 ONSD 值在 T1 时增加,此后趋于恢复基线值 ( < 0.001)。 : 我们得出结论,所有三种 SAD 都可以安全使用,因为它们在放置过程中既保持了血流动力学稳定,又保持了 ONSD 变化,并且不会导致 ONSD 升高到导致 ICP 增加的程度。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b46b/10146641/877b511dc87e/medicina-59-00753-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验