Suppr超能文献

一种新型羧基聚合物修饰的上转换发光纳米探针,通过流动免疫层析法用于检测临床灰色区域的前列腺特异性抗原。

A novel carboxyl polymer-modified upconversion luminescent nanoprobe for detection of prostate-specific antigen in the clinical gray zonebase by flow immunoassay strip.

机构信息

Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong 510000, China.

Shenzhen Light Life Technology Co., Ltd., Shenzhen 518107, China.

出版信息

Methods. 2023 Jul;215:10-16. doi: 10.1016/j.ymeth.2023.05.001. Epub 2023 May 9.

Abstract

Prostate specific antigen (PSA) is a widely-used biomarker for the diagnosis, screening, and prognosis of prostate cancer (PCa). It is critical to develop a rapid and convenient method to accurately detect PSA levels, especially when the PSA levels are in the clinical gray area of 4-10 ng/mL. We developed a novel upconversion nanoparticle (UCNP)-based fluorescence lateral flow test strip for qualitatively and quantitatively detecting PSA. The carboxyl group-modified UCNPs (UCNP-COOH) were labeled with anti-PSA antibodies via 1-ethyl-3-(3-(dimethylamino)propyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) as labeling probes to recognize PSA. The fluorescence intensity of the UCNP-probe was then measured with a laser fluorescence scanner. A total of 1397 serum and 20 fingertip blood samples were collected to validate the UCNP strip. A reliable correlation between the area ratio (TC), reflecting the fluorescence intensity of the test/control line, and the PSA concentration was observed (r = 0.9986). The dose-dependent luminescence enhancement showed good linearity in the PSA concentration range from 0.1 to 100.0 ng/mL with a detection limit of 0.1 ng/mL. Our UCNP POCT strip demonstrated excellent accuracy, anti-interference and stability in the gray zone (4-10 ng/mL) of PSA clinical application and outperformed other PSA test strips. The UCNP strip showed good consistency with the Roche chemiluminescence assay in 1397 serum samples. It also showed good performance for PSA detection using fingertip blood samples. This novel UCNP-based test strip could be a sensitive and reliable POCT assay to detect PSA, facilitating the diagnosis and surveillance of PCa.

摘要

前列腺特异性抗原(PSA)是一种广泛用于前列腺癌(PCa)诊断、筛查和预后的生物标志物。开发一种快速、便捷的方法来准确检测 PSA 水平至关重要,特别是当 PSA 水平处于 4-10ng/mL 的临床灰色区域时。我们开发了一种新型上转换纳米粒子(UCNP)基于荧光侧向流动测试条,用于定性和定量检测 PSA。通过 1-乙基-3-(3-(二甲基氨基)丙基)碳二亚胺(EDC)和 N-羟基琥珀酰亚胺(NHS)作为标记探针,将羧基修饰的 UCNP(UCNP-COOH)标记上抗 PSA 抗体,以识别 PSA。然后使用激光荧光扫描仪测量 UCNP 探针的荧光强度。共收集了 1397 份血清和 20 份指尖血样本用于验证 UCNP 条带。观察到测试线/控制线的荧光强度比(TC)与 PSA 浓度之间存在可靠的相关性(r=0.9986)。在 0.1 至 100.0ng/mL 的 PSA 浓度范围内,发光增强呈剂量依赖性,检测限为 0.1ng/mL。我们的 UCNP POCT 条带在 PSA 临床应用的灰色区域(4-10ng/mL)中表现出优异的准确性、抗干扰性和稳定性,优于其他 PSA 测试条。UCNP 条带在 1397 份血清样本中与罗氏化学发光法具有良好的一致性。它在手尖血样本中用于 PSA 检测也表现出良好的性能。这种新型基于 UCNP 的测试条可以作为一种敏感可靠的 POCT 检测 PSA 的方法,有助于 PCa 的诊断和监测。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验