采用 Biodex 测力计测量外展和旋转任务中等长肩部肌肉力量的重测信度。

Test-retest reliability of isometric shoulder muscle strength during abduction and rotation tasks measured using the Biodex dynamometer.

机构信息

Department of Biomedical Engineering, University of Basel, Basel, Switzerland; Department of Orthopaedics and Traumatology, University Hospital Basel, Basel, Switzerland.

Department of Orthopaedics and Traumatology, University Hospital Basel, Basel, Switzerland.

出版信息

J Shoulder Elbow Surg. 2023 Oct;32(10):2008-2016. doi: 10.1016/j.jse.2023.03.025. Epub 2023 May 11.

Abstract

BACKGROUND

The Constant score (CS) is often used clinically to assess shoulder function and includes a muscle strength assessment only for abduction. The aim of this study was to evaluate the test-retest reliability of isometric shoulder muscle strength during various positions of abduction and rotation with the Biodex dynamometer and to determine their correlation with the strength assessment of the CS.

METHODS

Ten young healthy subjects participated in this study. Isometric shoulder muscle strength was measured during 3 repetitions for abduction at 10° and 30° abduction in the scapular plane (with extended elbow and hand in neutral position) and for internal and external rotation (with the arm at 15° abduction in the scapular plane and elbow flexed at 90°). Muscle strength tests with the Biodex dynamometer were measured in 2 different sessions. The CS was acquired only in the first session. Intraclass correlation coefficients (ICCs) with 95% confidence interval, limits of agreement, and paired t tests for repeated tests of each abduction and rotation task were calculated. Pearson's correlation between the strength parameter of the CS and isometric muscle strength was investigated.

RESULTS

Muscle strength did not differ between tests (P > .05) with good to very good reliabilities for abduction at 10° and 30°, external rotation and internal rotation (ICC >0.7 for all). A moderate correlation of the strength parameter of the CS with all isometric shoulder strength parameters was observed (r > 0.5 for all).

CONCLUSION

Shoulder muscle strength for abduction and rotation measured with the Biodex dynamometer are reproducible and correlate with the strength assessment of the CS. Therefore, these isometric muscle strength tests can be further employed to investigate the effect of different shoulder joint pathology on muscle strength. These measurements consider a more comprehensive functionality of the rotator cuff than the single strength evaluation in abduction within the CS as both abduction and rotation are assessed. Potentially, this would allow for a more precise differentiation between the various outcomes of rotator cuff tears.

摘要

背景

常玉 score(CS)常用于评估肩部功能,仅包括外展肌力评估。本研究旨在评估 Biodex 测力计在不同外展和旋转位置下等长肩部肌肉力量的测试-重测信度,并确定其与 CS 肌力评估的相关性。

方法

10 名年轻健康受试者参与了本研究。在肩胛骨平面外展 10°和 30°(伸展肘部和手部处于中立位)以及内、外旋时,进行 3 次重复的等长肩部肌肉力量测量(手臂在肩胛骨平面外展 15°,肘部弯曲 90°)。在 2 个不同的时间段进行 Biodex 测力计的肌肉力量测试。CS 仅在第一次测试中获得。计算了每个外展和旋转任务的重复测试的组内相关系数(ICC)、一致性界限和配对 t 检验。研究了 CS 的肌力参数与等长肌肉力量之间的 Pearson 相关性。

结果

在测试之间肌肉力量没有差异(P>.05),外展 10°和 30°、外旋和内旋的可靠性良好至非常好(所有 ICC>0.7)。CS 的肌力参数与所有等长肩部力量参数均呈中度相关(所有 r>0.5)。

结论

使用 Biodex 测力计测量的肩部外展和旋转的肌肉力量具有可重复性,与 CS 的肌力评估相关。因此,这些等长肌肉力量测试可以进一步用于研究不同肩关节病变对肌肉力量的影响。与 CS 中外展的单一肌力评估相比,这些测量考虑了肩袖的更全面功能,因为在外展和旋转时都进行了评估。这可能会更精确地区分肩袖撕裂的各种结果。