Colver G B, Jones R L, Cherry G W, Dawber R P, Ryan T J
Br J Dermatol. 1986 May;114(5):603-8. doi: 10.1111/j.1365-2133.1986.tb04068.x.
Using an infrared coagulator, we have shown, in pigskin, a direct relationship between depth of injury and the duration of infra-red pulses, which was highly reproducible at a particular site. This has been related to the clinical results achieved in one patient whose three tattoos were treated with different pulse times.