Suppr超能文献

系统性硬化症患者单中心队列中的多参数皮肤评估:超高频率超声有作用吗?

Multiparametric Skin Assessment in a Monocentric Cohort of Systemic Sclerosis Patients: Is There a Role for Ultra-High Frequency Ultrasound?

作者信息

Di Battista Marco, Barsotti Simone, Vitali Saverio, Palma Marco, Granieri Giammarco, Oranges Teresa, Aringhieri Giacomo, Dini Valentina, Della Rossa Alessandra, Neri Emanuele, Romanelli Marco, Mosca Marta

机构信息

Rheumatology Unit, University of Pisa, 56124 Pisa, Italy.

Department of Medical Biotechnologies, University of Siena, 53100 Siena, Italy.

出版信息

Diagnostics (Basel). 2023 Apr 21;13(8):1495. doi: 10.3390/diagnostics13081495.

Abstract

: To assess skin involvement in a cohort of patients with systemic sclerosis (SSc) by comparing results obtained from modified Rodnan skin score (mRSS), durometry and ultra-high frequency ultrasound (UHFUS). : SSc patients were enrolled along with healthy controls (HC), assessing disease-specific characteristics. Five regions of interest were investigated in the non-dominant upper limb. Each patient underwent a rheumatological evaluation of the mRSS, dermatological measurement with a durometer, and radiological UHFUS assessment with a 70 MHz probe calculating the mean grayscale value (MGV). : Forty-seven SSc patients (87.2% female, mean age 56.4 years) and 15 HC comparable for age and sex were enrolled. Durometry showed a positive correlation with mRSS in most regions of interest ( = 0.025, ρ = 0.34 in mean). When performing UHFUS, SSc patients had a significantly thicker epidermal layer ( < 0.001) and lower epidermal MGV ( = 0.01) than HC in almost all the different regions of interest. Lower values of dermal MGV were found at the distal and intermediate phalanx ( < 0.01). No relationships were found between UHFUS results either with mRSS or durometry. : UHFUS is an emergent tool for skin assessment in SSc, showing significant alterations concerning skin thickness and echogenicity when compared with HC. The lack of correlations between UHFUS and both mRSS and durometry suggests that these are not equivalent techniques but may represent complementary methods for a full non-invasive skin evaluation in SSc.

摘要

通过比较改良罗德南皮肤评分(mRSS)、硬度计测量结果和超高频超声(UHFUS)获得的结果,评估一组系统性硬化症(SSc)患者的皮肤受累情况。:招募SSc患者和健康对照(HC),评估疾病特异性特征。在非优势上肢研究五个感兴趣区域。每位患者均接受了mRSS的风湿病学评估、用硬度计进行的皮肤病学测量以及用70 MHz探头进行的放射学UHFUS评估,计算平均灰度值(MGV)。:招募了47例SSc患者(87.2%为女性,平均年龄56.4岁)和15名年龄和性别匹配的HC。硬度计测量结果在大多数感兴趣区域与mRSS呈正相关(平均而言,P = 0.025,ρ = 0.34)。在进行UHFUS检查时,几乎在所有不同的感兴趣区域,SSc患者的表皮层明显更厚(P < 0.001),表皮MGV更低(P = 0.01)。在远端和中间指骨处发现真皮MGV值较低(P < 0.01)。未发现UHFUS结果与mRSS或硬度计测量结果之间存在相关性。:UHFUS是一种用于评估SSc患者皮肤的新兴工具,与HC相比,在皮肤厚度和回声性方面显示出显著改变。UHFUS与mRSS和硬度计测量结果之间缺乏相关性,表明这些不是等效技术,但可能代表用于SSc全无创皮肤评估的互补方法。