Suppr超能文献

使用消费者睡眠追踪器可靠估算习惯性睡眠所需的最少夜晚数。

Minimum number of nights for reliable estimation of habitual sleep using a consumer sleep tracker.

作者信息

Lau TeYang, Ong Ju Lynn, Ng Ben K L, Chan Lit Fai, Koek Daphne, Tan Chuen Seng, Müller-Riemenschneider Falk, Cheong Karen, Massar Stijn A A, Chee Michael W L

机构信息

Centre for Sleep and Cognition, Yong Loo Lin School of Medicine, National University of Singapore, 12 Science Drive 2, Singapore 117549, Singapore.

Health Promotion Board, 3 Second Hospital Ave, Singapore 168937, Singapore.

出版信息

Sleep Adv. 2022 Aug 31;3(1):zpac026. doi: 10.1093/sleepadvances/zpac026. eCollection 2022.

Abstract

STUDY OBJECTIVES

To determine the minimum number of nights required to reliably estimate weekly and monthly mean sleep duration and sleep variability measures from a consumer sleep technology (CST) device (Fitbit).

METHODS

Data comprised 107 144 nights from 1041 working adults aged 21-40 years. Intraclass correlation (ICC) analyses were conducted on both weekly and monthly time windows to determine the number of nights required to achieve ICC values of 0.60 and 0.80, corresponding to "good" and "very good" reliability thresholds. These minimum numbers were then validated on data collected 1-month and 1-year later.

RESULTS

Minimally, 3 and 5 nights were required to obtain "good" and "very good" mean weekly total sleep time (TST) estimates, while 5 and 10 nights were required for monthly TST estimates. For weekday-only estimates, 2 and 3 nights were sufficient for weekly time windows while 3 and 7 nights sufficed for monthly time windows. Weekend-only estimates of monthly TST required 3 and 5 nights. TST variability required 5 and 6 nights for weekly time windows, and 11 and 18 nights for monthly time windows. Weekday-only weekly variability required 4 nights for both "good" and "very good" estimates while monthly variability required 9 and 14 nights. Weekend-only estimates of monthly variability required 5 and 7 nights. Error estimates made using data collected 1-month and 1-year later with these parameters were comparable to those associated with the original dataset.

CONCLUSIONS

Studies should consider the metric, measurement window of interest, and desired reliability threshold to decide on the minimum number of nights required to assess habitual sleep using CST devices.

摘要

研究目的

确定使用消费者睡眠技术(CST)设备(Fitbit)可靠估计每周和每月平均睡眠时间及睡眠变异性指标所需的最少夜晚数。

方法

数据包括来自1041名年龄在21 - 40岁的在职成年人的107144个夜晚的数据。在每周和每月的时间窗口上进行组内相关系数(ICC)分析,以确定达到0.60和0.80的ICC值所需的夜晚数,这两个值分别对应“良好”和“非常好”的可靠性阈值。然后在1个月和1年后收集的数据上验证这些最少夜晚数。

结果

最少需要3个夜晚和5个夜晚才能分别获得“良好”和“非常好”的每周平均总睡眠时间(TST)估计值,而每月TST估计则需要5个夜晚和10个夜晚。仅针对工作日的估计,每周时间窗口需要2个夜晚和3个夜晚,而每月时间窗口需要3个夜晚和7个夜晚。仅针对周末的每月TST估计需要3个夜晚和5个夜晚。每周时间窗口的TST变异性需要5个夜晚和6个夜晚,每月时间窗口需要11个夜晚和18个夜晚。仅针对工作日的每周变异性,“良好”和“非常好”的估计都需要4个夜晚,而每月变异性需要9个夜晚和14个夜晚。仅针对周末的每月变异性估计需要5个夜晚和7个夜晚。使用1个月和1年后收集的数据以及这些参数进行的误差估计与原始数据集的误差估计相当。

结论

研究应考虑指标、感兴趣的测量窗口以及所需的可靠性阈值,以确定使用CST设备评估习惯性睡眠所需的最少夜晚数。