Suppr超能文献

不同测量方法在正常人群中评估 ISNT 规则及其变体的比较:一项横断面研究。

Comparison of different measuring methods in the assessment of the ISNT rule and its variants in a normal population: A cross-sectional study.

机构信息

Department of Physics, University of Beira Interior, Covilhã, Portugal.

Health Sciences Research Centre (CICS-UBI), University of Beira Interior, Covilhã, Portugal.

出版信息

Ophthalmic Physiol Opt. 2023 Sep;43(5):1190-1202. doi: 10.1111/opo.13171. Epub 2023 May 27.

Abstract

PURPOSE

The aim of this study was to compare five different neuroretinal rim (NRR) measurement methods, based on quadrants and NRR widths, in the assessment of the ISNT (inferior (I) > superior (S) > nasal (N) > temporal (T)) rule, and its variants IST (inferior (I) > superior (S) > temporal (S)) rule, IS (inferior (I) > superior (S)) rule and T (temporal is the thinnest) rule in a normal population. Factors influencing compliance with this rule and its variants were also evaluated.

METHODS

Stereoscopic fundus images were analysed through a dichoptic viewing system. Two graders labelled the optic disc and cup, as well as the fovea. Custom-made software automatically determined the limits of the optic disc and cup and examined the ISNT rule and its variants using several NRR measurement methods.

RESULTS

Sixty-nine subjects with normal eyes were enrolled. For the various NRR measuring methods, the percentage of eyes following the rules, that is, validity ranges were 0.0%-15.9% for the ISNT rule, 31.9%-59.4% for the IST rule, 46.4%-59.4% for the IS rule and 50.7%-100.0% for the T rule. Significant intra-measurement agreement ranges were IST (κ = 0.50-0.85), IS (κ = 0.68-1.00) and T (κ = 0.24-0.77). Only the IST and IS rules achieved significant inter-measurement agreement (κ = 0.47-1.00). After multivariate and receiver operating characteristic (ROC) curve analyses, the vertical cup position cup (area under the ROC curve (AUROC) = 0.60-0.96; cut-off = |0.005|) was the most important predictor for virtually all NRR measurement agreements for the ISNT, IST and IS rules. The horizontal cup position (AUROC = 0.50-0.92; cut-off = -0.028 to 0.05) was the most important predictive factor for the majority of the NRR measurement agreements for the T rule.

CONCLUSIONS

Only the IST and IS rules are valid for the same normal subjects. The most important factor affecting the validity of the ISNT rule and its variants was the anatomical cup position. NRR measurement agreements based on NRR quadrants exhibited larger validity and better agreement. The IST and IS rules can be combined with the alternative SIT (superior (S) > inferior (I) > temporal (T)) and SI (superior (S) > inferior (I)) rules to detect almost all normal subjects.

摘要

目的

本研究旨在比较五种不同的神经视网膜边缘(NRR)测量方法,基于象限和 NRR 宽度,评估 ISNT( inferior(I)> superior(S)> nasal(N)> temporal(T))规则及其变体 IST( inferior(I)> superior(S)> temporal(T))规则、IS( inferior(I)> superior(S))规则和 T( temporal 是最薄的)规则在正常人群中的应用。还评估了影响这些规则及其变体的一致性的因素。

方法

立体眼底图像通过双目视觉系统进行分析。两名评分员标记视盘和杯,以及黄斑。定制软件自动确定视盘和杯的边界,并使用几种 NRR 测量方法检查 ISNT 规则及其变体。

结果

共纳入 69 名正常眼受试者。对于各种 NRR 测量方法,符合规则的眼的百分比,即有效性范围为 ISNT 规则为 0.0%-15.9%,IST 规则为 31.9%-59.4%,IS 规则为 46.4%-59.4%,T 规则为 50.7%-100.0%。显著的内测量一致性范围为 IST(κ=0.50-0.85)、IS(κ=0.68-1.00)和 T(κ=0.24-0.77)。只有 IST 和 IS 规则达到了显著的间测量一致性(κ=0.47-1.00)。经过多变量和受试者工作特征(ROC)曲线分析,垂直杯位置杯(ROC 曲线下面积(AUROC)=0.60-0.96;截断值=|0.005|)是 ISNT、IST 和 IS 规则的几乎所有 NRR 测量一致性的最重要预测因子。水平杯位置(AUROC=0.50-0.92;截断值=-0.028 至 0.05)是大多数 T 规则 NRR 测量一致性的最重要预测因素。

结论

只有 IST 和 IS 规则适用于相同的正常受试者。影响 ISNT 规则及其变体一致性的最重要因素是解剖杯位置。基于 NRR 象限的 NRR 测量一致性具有更大的有效性和更好的一致性。IST 和 IS 规则可以与替代的 SIT( superior(S)> inferior(I)> temporal(T))和 SI( superior(S)> inferior(I))规则结合使用,以检测几乎所有正常受试者。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验