Department of Veterinary Clinical Sciences, The Ohio State University, Columbus, Ohio, USA.
Vet Surg. 2023 Oct;52(7):1015-1023. doi: 10.1111/vsu.13970. Epub 2023 Jun 6.
To assess oral buccal microcirculation by hand-held videomicroscopy in horses during colic surgery, comparing microcirculation values with macrocirculatory parameters and with those of healthy elective surgical horses.
Clinical prospective study.
Client-owned horses (nine in the colic group; 11 in the elective group).
In the colic group, buccal mucosal side stream dark-field microscopy (DFM) videos, cardiac output (CO), mean arterial pressure (MAP), and lactate were obtained at three timepoints under general anesthesia (30, 90, and 150 min after induction). Video analysis was used to determine total vessel density, proportion of perfused vessels, perfused vessel density, and heterogeneity index. Dark-field microscopy videos, MAP, and lactate were obtained at a single timepoint under general anesthesia (45 min after induction) in the elective group.
There were no differences in microcirculatory parameters between colic and elective horses, nor was there a difference across timepoints in the colic group. There was a weak negative correlation between microvascular parameters and CO (rho = -0.23).
The colic group did not have decreased microcirculation in comparison with the healthy elective group. Dark-field microscopy did not correlate well with macrocirculatory parameters in the colic group.
Dark-field microscopy may not be a sensitive enough indicator to detect differences in microcirculation between colic and elective groups. The lack of difference in microcirculation may be due to sample size, probe location, or variation in disease severity.
在手外科手术中评估马的口腔颊部微循环,通过手持式视频显微镜比较微循环值与大循环参数以及健康择期手术马的微循环值。
临床前瞻性研究。
客户拥有的马(绞痛组 9 匹;择期手术组 11 匹)。
在绞痛组中,在全身麻醉下(诱导后 30、90 和 150 分钟)获得颊黏膜侧流暗场显微镜(DFM)视频、心输出量(CO)、平均动脉压(MAP)和乳酸。使用视频分析来确定总血管密度、灌注血管比例、灌注血管密度和异质性指数。在全身麻醉下(诱导后 45 分钟)在择期手术组中获得暗场显微镜视频、MAP 和乳酸。
绞痛和择期手术马之间的微循环参数没有差异,绞痛组在各时间点之间也没有差异。微血管参数与 CO 之间存在弱负相关(rho=-0.23)。
与健康择期手术组相比,绞痛组的微循环没有减少。暗场显微镜与绞痛组的大循环参数相关性不佳。
暗场显微镜可能不足以作为检测绞痛和择期手术组之间微循环差异的敏感指标。微循环无差异可能是由于样本量、探头位置或疾病严重程度的差异所致。