Pediatric Cardiology, Gaziantep University Medical Faculty, Gaziantep, Turkey.
Pediatric Cardiology, Izmir Katip Celebi University Medical Faculty, Izmir, Turkey.
Cardiol Young. 2024 Jan;34(1):157-162. doi: 10.1017/S1047951123001385. Epub 2023 Jun 7.
In this multi-centre study, the mid- to long-term efficacy and safety of the Amplatzer Piccolo Occluder in patent ductus arteriosus closure in premature and term infants as well as children were discussed. Methods. Between 2016 and 2021, 645 patients, 152 of whom were less than 1 month old, underwent ductus closure with the Piccolo device from five different centres in Turkey. The median age of the patients was 2.2 years, and the mean narrowest point of duct diameter was 1.8 mm. Sixty-two patients weighed ≤ 1.5 kg, 90 patients 1.5-3 kg, and the mean follow-up was 20.4 months. In 396, the duct was closed by the retrograde route. Ductal anatomy was Type A in 285, C in 72, E in 171, and F in 64 patients. Fluoroscopy duration was 6.2 min. The procedure success rate was 99.1%. Device embolisation occurred in 13 patients (2%), and 11 were retrieved with a snare. Cardiac perforation and death developed in one premature baby. The left pulmonary artery and the descending aorta stenosis were observed in 3 (0.4%) and in 5 patients (0.5%). Results. Piccolo device is safe and effective in closing ductus in all age groups. It has low profile for use in premature and newborn babies, a small embolisation risk, and a low residual shunt rate after closure. Conclusion. The Piccolo device can be considered as close an ideal occluder. The lower profile, smaller delivery catheter size, and symmetry of this device allow for a venous or arterial approach.
在这项多中心研究中,讨论了 Amplatzer Piccolo 封堵器在早产儿和足月儿以及儿童中关闭动脉导管未闭的中-长期疗效和安全性。方法。在 2016 年至 2021 年期间,来自土耳其的五个不同中心的 645 名患者(其中 152 名患者年龄小于 1 个月)接受了 Piccolo 装置进行导管关闭。患者的中位年龄为 2.2 岁,导管最窄直径的平均值为 1.8 毫米。62 名患者体重≤1.5kg,90 名患者体重 1.5-3kg,平均随访时间为 20.4 个月。在 396 名患者中,导管通过逆行途径关闭。导管解剖类型为 A 型 285 例,C 型 72 例,E 型 171 例,F 型 64 例。透视时间为 6.2 分钟。手术成功率为 99.1%。13 名患者(2%)发生器械栓塞,其中 11 例用圈套器取出。1 例早产儿出现心脏穿孔和死亡。3 名(0.4%)和 5 名(0.5%)患者出现左肺动脉和降主动脉狭窄。结果。Piccolo 装置在所有年龄段关闭动脉导管均安全有效。对于早产儿和新生儿,它具有低轮廓,栓塞风险低,关闭后残余分流率低。结论。Piccolo 装置可被视为理想的封堵器。该装置的低轮廓、较小的输送导管尺寸和对称性允许经静脉或动脉入路。