后路交锁螺钉退出的处理:一种新型装置治疗逆行股骨髓内钉术后的病例系列研究。

Backout of Distal Interlocking Screws After Retrograde Femoral Nailing With a Novel Device: A Case Series.

机构信息

Department of Orthopaedic Surgery, Sports Medicine & Rehabilitation, Wright State University Boonshoft School of Medicine, Dayton, OH.

出版信息

J Orthop Trauma. 2023 Oct 1;37(10):500-505. doi: 10.1097/BOT.0000000000002646.

Abstract

OBJECTIVE

To report upon a series of patients who have experienced the backout of distal interlocking screws after retrograde femoral nailing with the DePuy Synthes RFN-Advanced Retrograde Femoral Nailing System (DePuy Synthes, Raynham, MA).

DESIGN

Retrospective case series.

PATIENTS

Twenty-seven skeletally mature patients with femoral shaft or distal femur fractures who underwent operative fixation with the DePuy Synthes RFN-Advanced Retrograde Femoral Nailing System with 8 patients subsequently experiencing backout of distal interlocking screws.

INTERVENTION

The study intervention included retrospective review of patient charts and radiographs.

MAIN OUTCOME MEASURE

The incidence rate of distal interlocking screw backout.

RESULTS

Thirty percent of patients experienced the backout of at least 1 distal interlocking screw (mean: 1.625) after undergoing retrograde femoral nailing with the RFN-Advanced system. Thirteen total screws backed out postoperatively. Screw backout was identified an average of 61 days postoperatively (range: 30-139 days). All patients complained of implant prominence and pain along the medial or lateral aspect of the knee. Five patients elected to return to the operating room to remove the symptomatic implant. The oblique distal interlocking screws comprised 62% of screw backouts.

CONCLUSIONS

Given the high incidence rate of this complication, the associated costs of reoperation, and patient discomfort, we believe that a further investigation into this implant complication is warranted.

LEVEL OF EVIDENCE

Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

摘要

目的

报告使用 DePuy Synthes RFN-Advanced Retrograde Femoral Nailing System(DePuy Synthes,雷纳姆,MA)进行逆行股骨髓内钉固定后,部分患者出现远端交锁螺钉退出的情况。

设计

回顾性病例系列。

患者

27 例骨骼成熟的股骨干或股骨远端骨折患者,使用 DePuy Synthes RFN-Advanced Retrograde Femoral Nailing System 进行手术固定,其中 8 例患者随后出现远端交锁螺钉退出。

干预措施

研究干预措施包括对患者病历和 X 线片进行回顾性审查。

主要观察指标

远端交锁螺钉退出的发生率。

结果

30%的患者在接受 RFN-Advanced 系统逆行股骨髓内钉固定后,至少有 1 枚远端交锁螺钉(平均 1.625 枚)退出。总共 13 枚螺钉术后退出。螺钉退出的平均时间为术后 61 天(范围:30-139 天)。所有患者均主诉出现植入物突出和膝关节内侧或外侧疼痛。5 名患者选择返回手术室取出有症状的植入物。斜向远端交锁螺钉占螺钉退出的 62%。

结论

鉴于这种并发症的高发生率、再次手术的相关成本以及患者的不适,我们认为有必要对这种植入物并发症进行进一步研究。

证据水平

治疗性 IV 级。有关证据水平的完整描述,请参见作者说明。