[ABG短柄与Corail长柄在Dorr C型股骨全髋关节置换术中的填充率、对线及稳定性比较]

[Comparison of filling ratio, alignment, and stability between ABG short-stem and Corail long-stem in total hip arthroplasty for Dorr type C femur].

作者信息

Bao Xianchao, Li Mingyang, Wu Limin, Jiang Shenghu, Shen Bin

机构信息

Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P. R. China.

出版信息

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2023 Jun 15;37(6):641-646. doi: 10.7507/1002-1892.202303123.

Abstract

OBJECTIVE

Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem.

METHODS

Among patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant ( >0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up ( >0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software.

RESULTS

X-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group ( <0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group ( <0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group ( <0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant ( >0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group ( <0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant ( >0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups ( >0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group ( <0.05).

CONCLUSION

Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.

摘要

目的

使用单能重建图像和X线片,研究与Corail长柄假体相比,ABGⅡ短柄假体能否提高Dorr C型股骨的填充率、稳定性和对线情况。

方法

在2006年1月至2012年3月期间接受全髋关节置换术的Dorr C型股骨患者中,随机选取20例使用Corail长柄假体的患者(Corail组)和20例使用ABGⅡ短柄假体的患者(ABGⅡ组)。两组患者在性别、年龄、体重指数和术前诊断方面的差异无统计学意义(P>0.05)。ABGⅡ组平均随访142个月(范围102 - 156个月),Corail组平均随访107个月(范围91 - 127个月)。末次随访时,两组患者的Harris评分和主观满意度评分差异无统计学意义(P>0.05)。末次随访时,采用双能CT扫描及单能图像重建计算假体填充率,并测量假体在冠状面和矢状面的对线情况。基于X线片进行稳定性评估,使用EBRA - FCA软件测量下沉距离。

结果

X线片观察显示两组假体均稳定,未发现松动迹象。ABGⅡ组基座征发生率显著低于Corail组(P<0.05),而异位骨化发生率显著高于Corail组(P<0.05)。ABGⅡ组股骨柄下沉距离显著大于Corail组(P<0.05),ABGⅡ组股骨柄下沉速度也大于Corail组,但差异无统计学意义(P>0.05)。ABGⅡ组整体假体填充率显著高于Corail组(P<0.05),而小转子处、小转子下方2 cm和小转子下方7 cm处的冠状面填充率差异无统计学意义(P>0.05)。假体对线结果显示,两组矢状面对线误差值以及冠状面和矢状面对线误差>3°的发生率差异无统计学意义(P>0.05),而ABGⅡ组冠状面对线误差值显著大于Corail组(P<0.05)。

结论

尽管ABGⅡ短柄假体避免了Corail长柄假体在Dorr C型股骨中远侧 - 近侧的不匹配,从而获得了更高的填充率,但似乎并未实现更好的对线或稳定性。

相似文献

本文引用的文献

6
Reproducibility of the Dorr classification and its quantitative indices on plain radiographs.平片 Dorr 分类及其定量指标的可重复性。
Orthop Traumatol Surg Res. 2019 Feb;105(1):17-21. doi: 10.1016/j.otsr.2018.11.008. Epub 2018 Dec 26.
8
Metal artifact reduction techniques in musculoskeletal CT-imaging.骨骼肌肉 CT 成像中的金属伪影降低技术。
Eur J Radiol. 2018 Oct;107:60-69. doi: 10.1016/j.ejrad.2018.08.010. Epub 2018 Aug 12.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验