Suppr超能文献

以卡波姆聚合物为乳腺体模材料的环氧树脂在低光子能量范围内衰减系数的测定

Determination of the Attenuation Coefficients of Epoxy Resin with Carbopol Polymer as a Breast Phantom Material at Low Photon Energy Range.

作者信息

Marashdeh Mohammad, Abdulkarim Muthanna

机构信息

Department of Physics, College of Sciences, Imam Mohammad Ibn Saud Islamic University (IMSIU), P.O. Box 90950, Riyadh 11623, Saudi Arabia.

Department of Pharmaceutical Sciences, College of Pharmacy, Alfaisal University, P.O. Box 50927, Riyadh 11533, Saudi Arabia.

出版信息

Polymers (Basel). 2023 Jun 11;15(12):2645. doi: 10.3390/polym15122645.

Abstract

Six different composites of epoxy resin and Carbopol 974p polymer were prepared based on Carbopol 974p polymer concentrations of 0%, 5%, 10%, 15%, 20%, and 25%. The linear and mass attenuation coefficients, Half Value Layer (HVL), and mean free path (MFP) of these composites were determined using single-beam photon transmission in the energy range between 16.65 keV and 25.21 keV. This was carried out by determining the attenuation of k X-ray fluorescent (XRF) photons from niobium, molybdenum, palladium, silver, and tin targets. The results were compared with theoretical values of three types of breast material (Breast 1, Breast 2, Breast 3) and Perspex, which was calculated using a XCOM computer program. The results show that there were no significant differences in the attenuation coefficient values after the consequent Carbopol additions. Moreover, it was found that the mass attenuation coefficients of all tested composites were close to those of Perspex and the values for Breast 3. The HVL and MFP results showed that the E25 sample is closer to the results of the Perspex material with differences of (0.53-1.15%) and (0.51-1.20%), respectively. In addition, the densities of the fabricated samples were in the range of 1.102-1.170 g/cm, which is in the range of human breast density. A computed tomography (CT) scanner was used to investigate the CT number values for the fabricated samples. The CT numbers of all samples were in the range of human breast tissue (24.53-40.28 HU). Based on these findings, the fabricated epoxy-Carbopol polymer is a good candidate for use as a breast phantom material.

摘要

基于卡波姆974p聚合物浓度为0%、5%、10%、15%、20%和25%,制备了六种不同的环氧树脂与卡波姆974p聚合物的复合材料。在16.65 keV至25.21 keV的能量范围内,通过单光束光子传输测定了这些复合材料的线性和质量衰减系数、半值层(HVL)和平均自由程(MFP)。这是通过测定来自铌、钼、钯、银和锡靶的k X射线荧光(XRF)光子的衰减来进行的。将结果与使用XCOM计算机程序计算的三种乳腺材料(乳腺1、乳腺2、乳腺3)和有机玻璃的理论值进行了比较。结果表明,在相继添加卡波姆后,衰减系数值没有显著差异。此外,发现所有测试复合材料的质量衰减系数接近有机玻璃和乳腺3的值。HVL和MFP结果表明,E25样品更接近有机玻璃材料的结果,差异分别为(0.53 - 1.15%)和(0.51 - 1.20%)。此外,所制备样品的密度在1.102 - 1.170 g/cm范围内,处于人类乳腺密度范围内。使用计算机断层扫描(CT)扫描仪研究了所制备样品的CT数值。所有样品的CT数值在人类乳腺组织范围内(24.53 - 40.28 HU)。基于这些发现,所制备的环氧 - 卡波姆聚合物是用作乳腺体模材料的良好候选材料。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3bfc/10301711/8e9d22804395/polymers-15-02645-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验