Suppr超能文献

植入式循环记录仪的远程监测可缩短不明原因晕厥患者的诊断时间:一项多中心倾向评分匹配研究。

Remote monitoring of implantable loop recorders reduces time to diagnosis in patients with unexplained syncope: a multicenter propensity score-matched study.

作者信息

Russo Vincenzo, Rago Anna, Grimaldi Nicola, Chianese Raffaele, Viggiano Aniello, D'Alterio Giuliano, Colonna Diego, Mattera Iacono Agostino, Papa Andrea Antonio, Spadaro Guerra Andrea, Gargaro Alessio, Rapacciuolo Antonio, Sarubbi Berardo, D'Onofrio Antonio, Nigro Gerardo

机构信息

Cardiology and Syncope Unit, Department of Medical Translational Sciences, University of Campania "Luigi Vanvitelli"-Monaldi Hospital, Naples, Italy.

Adult Congenital Heart Disease Unit, Monaldi Hospital, Naples, Italy.

出版信息

Front Cardiovasc Med. 2023 Jun 14;10:1193805. doi: 10.3389/fcvm.2023.1193805. eCollection 2023.

Abstract

BACKGROUND

There are little data on remote monitoring (RM) of implantable loop recorders (ILRs) in patients with unexplained syncope and whether it confers enhanced diagnostic power.

OBJECTIVE

To evaluate the effect of RM in ILR recipients for unexplained syncope for early detection of clinically relevant arrhythmias by comparison with a historical cohort with no RM.

METHODS

SyncRM is a propensity score (PS)-matched study prospectively including 133 consecutive patients with unexplained syncope and ILR followed up by RM (RM-ON group). A historical cohort of 108 consecutive ILR patients with biannual in-hospital follow-up visits was used as control group (RM-OFF group). The primary endpoint was the time to the clinician's evaluation of clinically relevant arrhythmias (types 1, 2, and 4 of the ISSUE classification).

RESULTS

The primary endpoint of arrhythmia evaluation was reached in 38 patients (28.6%) of the RM-ON group after a median time of 46 days (interquartile range, 13-106) and in 22 patients (20.4%) of the RM-OFF group after 92 days (25-368). The PS-matched adjusted ratio of rates of arrhythmia evaluation was 2.53 (95% confidence interval, 1.32-4.86) in the RM-ON vs. RM-OFF group ( = 0.005).

CONCLUSION

In our PS-matched comparison with a historical cohort, RM of ILR patients with unexplained syncope was associated with a 2.5-fold higher chance of evaluations of clinically relevant arrhythmias as compared with biannual in-office follow-up visits.

摘要

背景

关于不明原因晕厥患者植入式循环记录仪(ILR)的远程监测(RM)以及它是否能增强诊断能力的数据很少。

目的

通过与无RM的历史队列进行比较,评估RM对不明原因晕厥的ILR植入患者早期检测临床相关心律失常的效果。

方法

SyncRM是一项倾向评分(PS)匹配研究,前瞻性纳入133例连续的不明原因晕厥且接受ILR并通过RM进行随访的患者(RM-ON组)。将108例连续接受ILR且每半年进行一次院内随访的患者的历史队列作为对照组(RM-OFF组)。主要终点是临床医生对临床相关心律失常(ISSUE分类的1、2和4型)进行评估的时间。

结果

RM-ON组38例患者(28.6%)在中位时间46天(四分位间距,13 - 106天)后达到心律失常评估的主要终点,RM-OFF组22例患者(20.4%)在92天(25 - 368天)后达到该终点。RM-ON组与RM-OFF组心律失常评估率的PS匹配调整比值为2.53(95%置信区间,1.32 - 4.86)(P = 0.005)。

结论

在我们与历史队列的PS匹配比较中,与每半年进行一次门诊随访相比,不明原因晕厥的ILR患者的RM与临床相关心律失常评估机会高2.5倍相关。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e184/10303931/60a1c3841b49/fcvm-10-1193805-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验