Suppr超能文献

散光人工晶状体植入术后屈光不正的预测因素。

Factors Predictive of Refractive Error After Toric Lens Implantation.

作者信息

Gauthier Angela, Awidi Abdelhalim A, Noble Paige M, Daoud Yassine J

机构信息

Wilmer Eye Institute, Johns Hopkins Hospital, Baltimore, MD, USA.

Department of Ophthalmology, University of Iowa, Iowa City, IA, USA.

出版信息

Clin Ophthalmol. 2023 Jun 26;17:1813-1821. doi: 10.2147/OPTH.S407414. eCollection 2023.

Abstract

PURPOSE

To identify factors related to suboptimal refractive outcomes after toric intraocular lens implantation.

PATIENTS AND METHODS

A retrospective case-control chart review of 446 eyes with toric lens insertion by the same surgeon at a university hospital from 2016 to 2020 was conducted. Pre-operative exam findings, biometry, and one month and three month post-operative vision and refraction were noted. Reviewed charts were considered cases if uncorrected distance visual acuity (UDVA) was worse than 20/40, spherical equivalent (SE) >1 diopter (D) off target, or cylinder >1 D off target.

RESULTS

Overall, 93.7% (n = 343) of eyes achieved UDVA of 20/40 or better, 92.7% (n = 306) were within 1 D of target SE, and 90.9% (n = 300) were within 1 D of target cylinder. UDVA cases had more eyes with prior LASIK (21.7% vs 7.0%, p = 0.01) and keratoconus (8.7% vs 0.6%, p < 0.001) than controls. More SE cases had prior radial keratotomy (RK) (8.3% vs 0%, p < 0.001) and keratoconus (12.5% vs 0%, p < 0.001) than controls. More cylinder cases had prior LASIK (30.0% vs 8.7%, p < 0.001) and higher mean astigmatism (2.3 vs 1.5 D, p = 0.02) than controls. More cases in all three analyses had higher toric cylinder power (T5-T9) than controls. Age, sex, eye laterality, axial length, anterior chamber depth, lens power, dry eye, anterior basement membrane dystrophy, and Fuchs' endothelial dystrophy differences were not significant.

CONCLUSION

Prior LASIK or RK, keratoconus, and higher astigmatism may increase the chance of a suboptimal outcome.

摘要

目的

确定与环曲面人工晶状体植入术后屈光结果不理想相关的因素。

患者与方法

对2016年至2020年在一所大学医院由同一位外科医生进行环曲面晶状体植入的446只眼进行回顾性病例对照图表审查。记录术前检查结果、生物测量数据以及术后1个月和3个月的视力和屈光情况。如果未矫正远视力(UDVA)低于20/40、球镜等效度(SE)偏离目标超过1屈光度(D)或柱镜偏离目标超过1 D,则将审查的图表视为病例。

结果

总体而言,93.7%(n = 343)的眼睛UDVA达到20/40或更好,92.7%(n = 306)的眼睛SE在目标值1 D以内,90.9%(n = 300)的眼睛柱镜在目标值1 D以内。与对照组相比,UDVA病例中有更多眼睛曾接受过准分子激光原位角膜磨镶术(LASIK)(21.7%对7.0%,p = 0.01)和圆锥角膜(8.7%对0.6%,p < 0.001)。与对照组相比,更多SE病例曾接受过放射状角膜切开术(RK)(8.3%对0%,p < 0.001)和圆锥角膜(12.5%对0%,p < 0.001)。与对照组相比,更多柱镜病例曾接受过LASIK(30.0%对8.7%,p < 0.001)且平均散光更高(2.3对1.5 D,p = 0.02)。在所有三项分析中,更多病例的环曲面柱镜度数(T5 - T9)高于对照组。年龄、性别、眼别、眼轴长度、前房深度、晶状体度数、干眼、前弹力层营养不良和富克斯内皮营养不良差异均无统计学意义。

结论

既往LASIK或RK手术、圆锥角膜以及较高的散光可能会增加屈光结果不理想的几率。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7c3b/10312349/39f13b150e20/OPTH-17-1813-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验