State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, No. 14, 3rd Section of Renmin Nan Road, Chengdu, 610041, China.
Clin Oral Investig. 2023 Sep;27(9):5141-5151. doi: 10.1007/s00784-023-05134-8. Epub 2023 Jul 6.
This study evaluated the effect of offset on the precision of three-dimensional (3D)-printed splints, proposing to optimize the splint design to compensate for systematic errors.
14 resin model sets were scanned and offset as a whole by given distances (0.05, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35, and 0.40 mm). Intermediate splints (ISs) and final splints (FSs) were generated from the non-offset and offset models and grouped correspondingly, named as splint type-offset value, IS-0.05, for instance. Dentitions occluded with the splint were scanned. Translational and rotational deviations of the lower dentition relative to the upper dentition were 3D measured.
Deviations of ISs and FSs were more evident in the vertical and pitch dimensions, and were mostly acceptable in other dimensions. ISs with offset ≥ 0.05 mm showed vertical deviations significantly below 1 mm (P < 0.05) while ISs with 0.10- to 0.30-mm offsets had pitch rotations significantly lower than 1° (P < 0.05). The Pitch of IS-0.35 was significantly larger than ISs with 0.15- to 0.30-mm offsets (P < 0.05). Meanwhile, FSs fit better as the offset increased and FSs with offsets ≥ 0.15 mm all had deviations significantly lower than 1 mm (for translation) or 1° (for rotation) (P < 0.05).
Offset affects the precision of 3D-printed splints. Moderate offset values of 0.10 to 0.30 mm are recommendable for ISs. Offset values ≥ 0.15 mm are recommended for FSs in cases with stable final occlusion.
This study found the optimal offset ranges for 3D-printed ISs and FSs via a standardized protocol.
本研究评估了偏移对三维(3D)打印夹板精度的影响,提出优化夹板设计以补偿系统误差。
14 个树脂模型集被整体扫描并按给定距离(0.05、0.10、0.15、0.20、0.25、0.30、0.35 和 0.40mm)偏移。从中生成非偏移和偏移模型的中间夹板(IS)和最终夹板(FS),并相应分组,例如 IS-0.05。用夹板咬合的牙列被扫描。下牙列相对于上牙列的平移和旋转偏差进行了 3D 测量。
IS 和 FS 的偏差在垂直和俯仰尺寸上更为明显,在其他尺寸上大多可以接受。偏移≥0.05mm 的 IS 显示垂直偏差明显低于 1mm(P<0.05),而 0.10-0.30mm 偏移的 IS 具有明显低于 1°的俯仰旋转(P<0.05)。IS-0.35 的 Pitch 明显大于 0.15-0.30mm 偏移的 ISs(P<0.05)。同时,随着偏移的增加,FS 更贴合,偏移≥0.15mm 的 FS 所有偏差均明显低于 1mm(用于平移)或 1°(用于旋转)(P<0.05)。
偏移会影响 3D 打印夹板的精度。IS 推荐使用 0.10-0.30mm 的中等偏移量。对于最终咬合稳定的病例,建议使用 FS 的偏移量≥0.15mm。
本研究通过标准化方案确定了 3D 打印 IS 和 FS 的最佳偏移范围。