Abstract

Anastomoses of the coronary buttons are the Achilles' heel of the modified Bentall procedure (MBP) for the repair of the aortic root and ascending aorta. We present a rare case of post-MBP right coronary artery button pseudoaneurysm in a 30-year-old man. The contained leak, attributed to a pseudoknot in the polypropylene suture, was visualized via computed tomography angiography and transesophageal echocardiogram and repaired under deep hypothermic circulatory arrest.

摘要

冠状动脉纽扣状吻合是改良Bentall手术(MBP)修复主动脉根部和升主动脉的薄弱环节。我们报告了一例30岁男性在MBP术后发生右冠状动脉纽扣状假性动脉瘤的罕见病例。通过计算机断层扫描血管造影和经食管超声心动图发现,渗漏是由聚丙烯缝线中的假结引起的,并在深低温停循环下进行了修复。